Evidence map›Paper›PMID 39758195›Full record

ArticleFrontiers in public health2024

Automated approach for fetal and maternal health management using light gradient boosting model with SHAP explainable AI.

Nisreen Innab, Shtwai Alsubai, Ebtisam Abdullah Alabdulqader, Aisha Ahmed Alarfaj, Muhammad Umer, Silvia Trelova, Imran Ashraf

Abstract read
In one paragraph

Article in Frontiers in public health, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nisreen InnabDepartment of Computer Science and Information Systems, College of Applied Sciences, AlMaarefa University, Diriyah, Riyadh, Saudi Arabia.
Shtwai AlsubaiDepartment of Computer Science, College of Computer Engineering and Sciences, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia.
Ebtisam Abdullah AlabdulqaderDepartment of Information Technology, College of Computer and Information Sciences, King Saud University, Riyadh, Saudi Arabia.
Aisha Ahmed AlarfajDepartment of Information Systems, College of Computer and Information Sciences, Princess Nourah Bint Abdulrahman University, Riyadh, Saudi Arabia.
Muhammad UmerDepartment of Computer Science and Information Technology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
Silvia TrelovaFaculty of Management, Comenius University Bratislava, Bratislava, Slovakia.
Imran AshrafDepartment of Information and Communication Engineering, Yeungnam University, Gyeongsan, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fetal health holds paramount importance in prenatal care and obstetrics, as it directly impacts the wellbeing of mother and fetus. Monitoring fetal health through pregnancy is crucial for identifying and addressing potential risks and complications that may arise. Early detection of abnormalities and deviations in fetal health can facilitate timely interventions to mitigate risks and improve outcomes for the mother and fetus. Monitoring fetal health also provides valuable insights into the effectiveness of prenatal interventions and treatments. For fetal health classification, this research work makes use of cardiotocography (CTG) data containing 21 features including fetal growth, development, and physiological parameters such as heart rate and movement patterns with three target classes "normal," "suspect," and "pathological." The proposed methodology makes use of data upsampled using the synthetic minority oversampling technique (SMOTE) to handle the class imbalance problem that is very crucial in medical diagnosing with a light gradient boosting machine. The results show that the proposed model gives 0.9989 accuracy, 0.9988 area under the curve, 0.9832 recall, 0.9834 precision, 0.9832 F1 score, 0.9748 Kappa score, and 0.9749 Matthews correlation coefficient value on the test dataset. The performance of the proposed model is compared with other machine learning models to show the dominance of the proposed model. The proposed model's significance is further evaluated using 10-fold cross-validation and comparing the proposed model with other state-of-the-art models.

Indexed as

Maternal HealthCardiotocographyFemaleHumansMachine LearningPregnancyPrenatal Carehealthcaremachine learningmother and child carepublic healthrisk perceptions

Identifiers

PMID39758195
PMCPMC11695363

What OpenQuestion holds

Textmetadata
LicenceCC BY