ArticleLasers in surgery and medicine2025
3D Finite Element Modeling of Femtosecond Laser Trabeculotomy.
Article in Lasers in surgery and medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectivesFemtosecond laser image guided high precision trabeculotomy (FLigHT) is a novel open-angle glaucoma treatment. The procedure non-invasively creates aqueous humor (AH) drainage channel from the anterior chamber (AC) to Schlemm's canal (SC) through the trabecular meshwork (TM) to decrease intraocular pressure (IOP). The purpose of this study was to develop a 3D finite element model (FEM) of the FLigHT procedure and to simulate clinical results for different drainage channel cross-sectional areas.
methodsFirst, a FEM model of the average intact glaucomatous eye was constructed. Biometric data published in the literature were used to construct the geometry of the model, including the AC, TM, SC, and collector channels (CCs). The TM and CCs were modeled as porous material, with given permeability, to approximate the outflow resistance found in these tissues in-vivo. The permeability of the TM and CCs was estimated by comparing iterative FEM simulations with published clinical FLigHT IOP data. For that, the model was modified to simulate the FLigHT treatment of glaucoma by applying a block-like channel connecting the AC to the SC. Channel size was varied from the clinically utilized size of 200 µm × 500 µm down to 50 µm × 50 µm to investigate the effects of channel size on resultant IOP.
resultsThe model revealed that the minimum achievable IOP after FLigHT is the preoperative pressure in SC. It is independent of TM permeability; rather, it depends on CC permeability, AH inflow rate, and episcleral venous pressure. In addition, simulations predicted that a channel size of 100 μm × 100 μm is sufficient to obtain the maximum achievable IOP reduction. Beyond this size, no appreciable increase in IOP reduction was achieved.
conclusionsThe 3D FEM developed in this study provided an adequate simulation of the IOP reduction of the FLigHT treatment, demonstrating its predictive power regarding drainage channel geometry and subsequent IOP reduction. The results indicate that the model has the potential to aid the design of clinical FLigHT procedures.