Evidence map›Paper›PMID 39754368›Full record

ArticleAnimal models and experimental medicine2025

Intratracheal instillation for the testing of pulmonary toxicity in mice-Effects of instillation devices and feed type on inflammation.

Niels Hadrup, Michael Guldbrandsen, Eva Terrida, Katja M S Bendtsen, Karin S Hougaard, Nicklas R Jacobsen, Ulla Vogel

Abstract read
In one paragraph

Article in Animal models and experimental medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Niels HadrupNational Research Centre for the Working Environment, Copenhagen, Denmark.ORCID 0000-0002-1188-445X
Michael GuldbrandsenNational Research Centre for the Working Environment, Copenhagen, Denmark.
Eva TerridaNational Research Centre for the Working Environment, Copenhagen, Denmark.
Katja M S BendtsenNational Research Centre for the Working Environment, Copenhagen, Denmark.
Karin S HougaardNational Research Centre for the Working Environment, Copenhagen, Denmark.
Nicklas R JacobsenNational Research Centre for the Working Environment, Copenhagen, Denmark.
Ulla VogelNational Research Centre for the Working Environment, Copenhagen, Denmark.

Funding

Focused Research Effort on Chemicals in the Working Environment (FFIKA) from the Danish Government
6 · The paper itself

Abstract

backgroundInhalation exposure is the gold standard when assessing pulmonary toxicity. However, it typically requires substantial amounts of test material. Intratracheal instillation is an alternative administration technique, where the test substance is suspended in a liquid vehicle and deposited into the lung via the trachea. Instillation requires minimal test material, delivers an exact dose deep into the lung, and is less labor-intensive than inhalation exposures. However, one shortcoming is that the procedure may induce short-term inflammation. To minimize this, we tested different modifications of the technique to identify the potential for refinement.

methodsFirst, we tested whether previous findings of increased inflammation could be confirmed. Next, we tested whether instillation with a disposable 1 mL syringe with ball-tipped steel-needle (Disposable-syringe/steel-needle) induced less inflammation than the use of our standard set-up, a 250 μL reusable glass syringe with a disposable plastic catheter (Glass-syringe/plastic-catheter). Finally, we tested if access to pelleted and liquid feed prior to instillation affected inflammation. We evaluated inflammation by neutrophil numbers in bronchoalveolar fluid 24 h post-exposure.

resultsVehicle-instilled mice showed a small increase in neutrophil numbers compared to untreated mice. Neutrophil numbers were slightly elevated in the groups instilled with Disposable-syringe/steel-needle; an interaction with feed type indicated that the increase in neutrophils was more pronounced in combination with feed pellets compared to liquid feed. We found no difference between the feed types when using the Glass-syringe/plastic-catheter combination.

conclusionThe Glass-syringe/plastic-catheter combination induced the least exposure-related inflammation, confirming this as a preferred instillation procedure.

Indexed as

Animal FeedInflammationIntubation, IntratrachealLungPneumoniaToxicity TestsAnimalsBronchoalveolar Lavage FluidFemaleInhalation ExposureMaleMiceMice, Inbred C57BLNeutrophilsTracheainhalationmousepulmonarytoxicity

Identifiers

PMID39754368
PMCPMC11871123

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.