Evidence map›Paper›PMID 39752034›Full record

ArticleJournal of robotic surgery2025

Safety and clinical efficacy of modified tracer fixation technique in orthopedic robot-assisted percutaneous vertebroplasty for Kümmell's disease.

Xuebin Tang, Chengqiang Zhou, Hua Li, Yifeng Liao, Liang Qiao, Junwei Zhang, Yunqing Wang, Lin Xie

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xuebin Tang *Department of Orthopaedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China.
Chengqiang Zhou *Department of Orthopaedics, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China.
Hua LiDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, Jiangsu, China.
Yifeng LiaoDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, Jiangsu, China.
Liang QiaoDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, Jiangsu, China.
Junwei ZhangDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, Jiangsu, China.
Yunqing WangDepartment of Orthopaedics, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221000, Jiangsu, China. wang.yunqing@163.com.
Lin XieDepartment of Orthopaedics, Affiliated Hospital of Integrated Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Nanjing, 210028, Jiangsu, China. xielin6508@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The rising incidence of osteoporotic vertebral compression fractures (OVCF) has increased the demand for precise treatments like robot-assisted percutaneous vertebroplasty (PVP), especially for conditions like Kümmell's disease that require high surgical accuracy. However, the traditional tracer fixation method has certain limitations. This study aimed to compare the safety and clinical efficacy of a modified tracer fixation technique with the traditional fixation method in robot-assisted percutaneous vertebroplasty (PVP) for Kümmell's disease. A retrospective analysis was conducted on 88 patients treated between April 2023 and January 2024. The patients were divided into two groups based on the tracer fixation method: the modified group (skin-fixed, 47 cases) and the traditional group (spinous process-fixed, 41 cases). Outcomes were measured by VAS, ODI, Cobb angle, working channel establishment time, surgical duration, intraoperative blood loss, intraoperative fluoroscopy dose, and complication rates. Both groups showed significant improvements in VAS, ODI, and Cobb angle at postoperative days 2 and 6 months (P < 0.05). The modified group had significantly lower VAS and ODI scores on postoperative days 2, shorter working channel establishment and surgical duration, and less intraoperative blood loss (P < 0.05). However, no significant differences were found in intraoperative fluoroscopy dose or complication rates (P > 0.05). In conclusion, while both techniques are safe and effective, the modified skin-fixed tracer technique offers advantages in reducing surgical trauma, significantly shortening the surgical duration, decreasing intraoperative blood loss, and promoting early recovery.

Indexed as

Fractures, CompressionRobotic Surgical ProceduresSpinal FracturesVertebroplastyAgedAged, 80 and overBlood Loss, SurgicalFemaleHumansMaleMiddle AgedOsteoporotic FracturesRetrospective StudiesTreatment OutcomeKümmell’s diseaseOrthopedic roboticsOsteoporotic vertebral compression fracturesPercutaneous vertebroplastyTracer

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.