Evidence map›Paper›PMID 39751967›Full record

ArticleJournal of medical systems2025

Development and Validation of a Neurosurgical Phantom for Simulating External Ventricular Drain Placement.

Jesse A M van Doormaal, Tim Fick, Ernest Boskovic, Eelco W Hoving, Pierre A J T Robe, Tristan P C van Doormaal

Abstract readValidation Study
In one paragraph

Article in Journal of medical systems, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jesse A M van DoormaalDepartment of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands. j.a.m.vandoormaal-2@umcutrecht.nl.ORCID http://orcid.org/0000-0002-9531-2765
Tim FickDepartment of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0001-8900-7492
Ernest BoskovicDepartment of Medical Technology and Clinical Physics, University Medical Centre Utrecht, Utrecht, The Netherlands.
Eelco W HovingDepartment of Neuro-Oncology, Princess Máxima Centre for Pediatric Oncology, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-5587-0439
Pierre A J T RobeDepartment of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0001-7845-6196
Tristan P C van DoormaalDepartment of Neurosurgery, University Medical Centre Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-6299-3859

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements. The effectiveness of the phantom as a training tool was assessed through a standardized user experience questionnaire, which evaluated the physical attributes, realism, and overall satisfaction. The mechanical properties of the phantom brain were quantified by measuring catheter insertion forces using a linear force tester to compare them to those experienced in real brain tissue. The study participants successfully completed EVD placements with a 76.7% optimal placement rate, which aligns with rates observed in clinical practice. Feedback highlighted the anatomical accuracy of the phantom and its value in enhancing surgical skills, though it also identified areas for improvement, particularly in the realism of the skin layer. Mechanical testing demonstrated that the insertion forces required were comparable to those encountered in actual brain tissue. The developed phantom offers a realistic, low-cost, and adaptable model for EVD simulation. This tool is particularly beneficial for both training and research, with future enhancements planned to improve the realism of the skin and incorporate more anatomical features to increase the fidelity of the simulation.

Indexed as

Phantoms, ImagingBrainClinical CompetenceDrainageHumansMagnetic Resonance ImagingModels, AnatomicPrinting, Three-DimensionalVentriculostomyExternal Ventricular DrainSurgical PhantomSurgical SimulationSurgical TrainingVentriculostomy

Identifiers

PMID39751967
PMCPMC11698783

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.