Evidence map›Paper›PMID 39749100›Full record

ArticleCeramics2022

Three-Dimensional Finite Element Analysis of Different Connector Designs for All-Ceramic Implant-Supported Fixed Dental Prostheses.

Laura H J Alberto, Lohitha Kalluri, Josephine F Esquivel-Upshaw, Yuanyuan Duan

Abstract read
In one paragraph

Article in Ceramics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Laura H J AlbertoDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.ORCID 0000-0003-4483-9636
Lohitha KalluriDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.ORCID 0000-0002-1692-5177
Josephine F Esquivel-UpshawDepartment of Restorative Dental Sciences, Division of Prosthodontics, University of Florida, Gainesville, FL 32611, USA.ORCID 0000-0003-3642-8087
Yuanyuan DuanDepartment of Biomedical Materials Science, University of Mississippi Medical Center, Jackson, MS 39216, USA.

Funding

Using social networks to map and evaluate team science across CTSA hubsUL1TR001427 · NCATS · UNIVERSITY OF FLORIDA · PI MITCHELL, DUANE A. · 2015 to 2024
$37.2M
Novel coatings to minimize surface degradation and fracture susceptibility of dental ceramicsR01DE025001 · NIDCR · UNIVERSITY OF FLORIDA · PI ESQUIVEL-UPSHAW, JOSEPHINE F. · 2016 to 2020
$4.2M
Novel coated nanostructured implant surfaces to increase osseointegration and decrease peri-implantitis in a physiologic rat modelR56DE025001 · NIDCR · UNIVERSITY OF FLORIDA · PI ESQUIVEL-UPSHAW, JOSEPHINE F. · 2022 to 2022
$650k
NCATS NIH HHS UL1 TR001427NIDCR NIH HHS R01 DE025001NIDCR NIH HHS R56 DE025001
6 · The paper itself

Abstract

All-ceramic fixed dental prostheses (FDPs) tend to fracture at the connector regions due to high stress concentration at these areas influenced by their design. This study was performed as an adjunct to an existing clinical study to evaluate the influence of the different radii of curvature of gingival embrasure on the stress distribution of a three-unit all-ceramic implanted supported FDP. Three three-dimensional (3D) models were created by scanning two titanium dental implants, their suitable zirconia abutments, and a patient-retrieved dental prosthesis using a micro-CT scanner. The radius of curvature of the gingival embrasure for the distal connector of the FDP was altered to measure 0.25 mm, 0.50 mm, and 0.75 mm. A finite element analysis (FEA) software (ABAQUS) was used to evaluate the impact of different connector designs on the distribution of stresses. Maximum Principal Stress data was collected from the individual components (veneer, framework, and abutments). The radius of curvature of gingival embrasure had a significant influence on the stress distribution at the assessed components. The tensile peak stresses at all structures were highest in the 0.25 mm model, while the 0.50 mm and 0.75 mm models presented similar values and more uniform stress distribution.

Indexed as

all-ceramic FPDconnector designdental implantsfinite element analysisgingival embrasure

Identifiers

PMID39749100
PMCPMC11694178

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.