Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength.

Francesco Sartorio, Lorenzo Lippi, Stefano Vercelli, Federica Gallo, Davide Zanin, Sara Bergesio, Alessandro de Sire, Marco Invernizzi

Abstract readValidation Study
In one paragraph

Article in BMC musculoskeletal disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Francesco SartorioDivision of Physical Medicine and Rehabilitation, ICS Maugeri SPA SB, Institute of Veruno, IRCCS, 28010, Novara, Veruno, Italy.
Lorenzo LippiDepartment of Scientific Research, Campus LUdeS, Off-Campus Semmelweis University of Budapest, Budapest, 1085, Hungary. lorenzo.lippi@uniludes.ch.
Stefano VercelliRehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern, 6928, Manno, Lugano, Switzerland.
Federica GalloEpidemiology Unit, Local Health Authority 1 of Cuneo, 12100, Cuneo, Italy.
Davide ZaninHand Surgery and Microsurgery Unit, Humanitas - Clinica Fornaca Di Sessant, 10128, Turin, Italy.
Sara BergesioExtended Care "Chianoc", 12038, Savigliano, Cuneo, Italy.
Alessandro de SireDepartment of Medical and Surgical Sciences, University of Catanzaro "Magna Graecia", 88100, Catanzaro, Italy.
Marco InvernizziDepartment of Health Sciences, University of Eastern Piedmont, 28100, Novara, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar® hydraulic dynamometer (JD), the gold standard.

methodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices. To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.

resultsAll ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland-Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD.

conclusionsNOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth® connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.

Indexed as

Hand StrengthMuscle Strength DynamometerAdultFemaleHealthy VolunteersHumansIsometric ContractionMaleMiddle AgedReproducibility of ResultsYoung AdultDigital InnovationHand grip strengthHealth TechnologyRehabilitation

Identifiers

PMID39748317
PMCPMC11694367

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.