Evidence map›Paper›PMID 39748067›Full record

ArticleScientific reports2025

Optimizing electrode configurations for EEG mild cognitive impairment detection.

Yi Jiang, Xin Zhang, Zhiwei Guo, Xiaobo Zhou, Jiayuan He, Ning Jiang

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review of Recent Advances in Implantable Brain-Computer Interfaces for the Restoration of Motor Function in Patients With Paralysis.Medical science monitor : international medical journal of experimental and clinical research · 2026
    Review
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yi JiangThe National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
Xin ZhangThe College of Bioengineering, the Key Laboratory of Biorheological Science and Technology, Ministry of Education, Chongqing University, Chongqing, 400000, China.
Zhiwei GuoThe National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China.
Xiaobo ZhouCenter for Computational Systems Medicine, McWilliams School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, TX, 77030, USA.
Jiayuan HeThe National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China. jiayuan.he@wchscu.cn.
Ning JiangThe National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, 610041, Sichuan, China. wearablemedical@wchscu.cn.

Funding

National Clinical Medical Research Center for Geriatric Diseases 1.3.5 Y2023YY006the National Natural Science Foundation of China 62206032
6 · The paper itself

Abstract

The Optimal electrode configuration of Electroencephalograms (EEG) systems for mild cognitive impairment (MCI) detection and monitoring in non-clinical settings, i.e. number of electrodes and the positions of the electrodes, remains to be explored. In the current study, we explored the optimization of electrode configuration for MCI detection. We used a 32-channel EEG device to record the data of 21 MCI patients and 20 cognitively normal elderly (NC) undergoing working memory (WM) tasks. Based on the differential value (MCI group vs. NC group) from the Power Spectral Density (PSD) value of each electrode in θ and α frequency band during WM coding stage, six different electrode configurations were obtained: (1) four electrodes in the occipital lobe (OCL4); (2) three electrodes in the prefrontal lobe (PRL3); (3) four electrodes in the parietal lobe (PLL4), (4) eight electrodes in occipital combined parietal lobe (OPL8), (5) seven electrodes in occipital combined prefrontal lobe (OPL7); and (6) seven electrodes in parietal combined prefrontal lobe (PPL7). A multi-parameter combination-assisted binary logistic regression model was established to distinguish two groups. Receiver operating characteristic (ROC) curves were used to evaluate the MCI diagnostic power of each electrode configuration. The area under curve (AUC) of the ROC of electrode configurations OCL4, PRL3, PLL4, OPL8, OPL7 and PPL7 were 0.765, 0.683, 0.729, 0.83, 0.788, and 0.769, respectively. And the sensitivity of six electrode configurations were 0.962, 0.794, 0.873, 0.943, 0.859, and 0.938, respectively. Among these six configurations, OCL4, i.e. PO3, PO4, PO8, and PO7, had the highest sensitivity 96.2%, which meant that relying solely on these four electrodes of the occipital lobe had the potential to serve as an objective tool for preliminary screening of MCI. The abnormal brain rhythm characteristics of the frontal, parietal, and occipital lobes in the memory encoding stage of MCI provide a new perspective for MCI-WM impairment, which has the potential to be a novel biomarker for the early detection of pathological age-related cognitive decline. Further, a potential four-electrode configuration may be used for a novel detecting and monitoring EEG system of MCI in non-clinical settings.

Indexed as

Cognitive DysfunctionElectrodesElectroencephalographyAgedAged, 80 and overFemaleHumansMaleMemory, Short-TermMiddle AgedROC CurveElectroencephalographyMild cognitive impairmentWearable EEG deviceWorking memory

Identifiers

PMID39748067
PMCPMC11696624

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.