Evidence map›Paper›PMID 39747801›Full record

ArticleEuropean radiology experimental2025

Comparison of CT-like MRI sequences for preoperative planning of cochlear implantation using super-high-resolution CT as a reference.

Ulysse Puel, Achille Beysang, Gabriella Hossu, Michael Eliezer, Bouchra Assabah, Khalid Ambarki, Pedro Augusto Gondim Teixeira, Alain Blum, Cécile Parietti-Winkler, Romain Gillet

Abstract readComparative Study
In one paragraph

Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ulysse PuelGuilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France. ulysse.puelpro@gmail.com.ORCID http://orcid.org/0000-0003-2773-3514
Achille BeysangGuilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Gabriella HossuCIC, Innovation Technologique, Université de Lorraine, University Hospital Center of Nancy, Nancy, France.
Michael EliezerDepartment of Radiology, Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts, 28 Rue de Charenton, 75012, Paris, France.
Bouchra AssabahFaculty of Medicine and University Hospital, Department of Anatomy, University of Lorraine, 9 Avenue de la Forêt de Haye, 54500, Vandœuvre-lès-Nancy, France.
Khalid AmbarkiSiemens Healthcare SAS, Saint Denis, France.
Pedro Augusto Gondim TeixeiraGuilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Alain BlumGuilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.
Cécile Parietti-WinklerDepartment of Otorhinolaryngology, Head and Neck Surgery, University Hospital, 29 avenue du Maréchal de Lattre de Tassigny, 54035, Nancy Cedex, France.
Romain GilletGuilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, 29 Avenue du Marechal de Lattre de Tassigny, 54000, Nancy, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe evaluated the accuracy of magnetic resonance imaging (MRI) computed tomography (CT)-like sequences compared to normal-resolution CT (NR-CT) and super-high-resolution CT (SHR-CT) for planning of cochlear implantation.

methodsSix cadaveric temporal bone specimens were used. 3-T MRI scans were performed using radial volumetric interpolated breath-hold (STARVIBE), pointwise-encoding time reduction with radial acquisition (PETRA), and ultrashort time of echo (UTE) sequences. CT scans were performed on two scanners for SHR-CT and NR-CT acquisitions. Two radiologists evaluated accuracy based on preimplantation metrics and the ability to identify various anatomical structures, particularly the facial recess and round window. Wilcoxon rank-sum test and intraclass correlation coefficient (ICC) were used.

resultsThe facial nerve was always clearly visible (score ≥ 2) in the MRI, NR-CT, and SHR-CT scans (p ≥ 0.621). However, the chorda tympani nerve (CTN) was clearly visualized in UTE, STARVIBE, and PETRA sequences in only 33% (2/6 specimens, p = 0.016), 50% (3/6 specimens, p = 0.038), and 83% (5/6 specimens, p = 0.017) of cases, respectively, whereas it was always clearly visualized in SHR and NR-CT (p = 0.426). The round window (RW) was never visualized in MRI sequences (p ≤ 0.010), whereas it was identified in all cases in SHR and NR-CT (p = 1.000). There was a strong correlation between measurements obtained from MRI and CT modalities (ICC ≥ 0.837).

conclusionMRI CT-like sequences assessed the facial nerve in all cases and the CTN in up to 87% of cases. However, the detection of the RW was insufficient for surgical planning. CT and MRI measurements were in agreement. RELEVANCE STATEMENT: CT-like MRI sequences can image the anatomy of the facial recess and the length of the basal turn of the cochlea with similar accuracy as conventional CT, although they cannot image the round window. KEY POINTS: CT-like MRI sequences are not widely used in preoperative cochlear implantation imaging. CT-like sequences can image the facial recess as well as conventional CT. CT-like sequences can image the basal turn length of the cochlea as well as conventional CT. Round window depiction is not possible with CT-like MRI sequences.

Indexed as

CadaverCochlear ImplantationMagnetic Resonance ImagingTomography, X-Ray ComputedHumansPreoperative CareTemporal BoneChorda tympani nerveCochlear implantationComputed tomographyFacial nerveMagnetic resonance imaging

Identifiers

PMID39747801
PMCPMC11695506

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.