Evidence map›Paper›PMID 39745654›Full record

ReviewEJNMMI physics2025

The SwiftScan step-and-shoot continuous mode improves SPECT scanning efficiency: a preliminary phantom and clinical test.

Jicheng Li, Kai Zhang, Xingru Pang, Lele Huang, Xiaoxue Tian, Jiangyan Liu

Abstract readReview
In one paragraph

Review in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jicheng Li *Department of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Kai Zhang *Department of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Xingru PangDepartment of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Lele HuangDepartment of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Xiaoxue TianDepartment of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China.
Jiangyan LiuDepartment of Nuclear Medicine, Lanzhou University Second Hospital, Lanzhou, 730030, China. ery_liujy@lzu.edu.cn.

Funding

Key Science and Technology Foundation of Gansu Province 23YFMA0009Lanzhou University Second Hospital CY2022-QN-A19Lanzhou University Second Hospital CY2023-MS-B10Science and Technology Department of Gansu Province 24JRRA922
6 · The paper itself

Abstract

purposeThe aim of the study was to investigate the value of SwiftScan Step-and-Shoot Continuous (SSC) scanning mode in enhancing image quality and to explore appropriate scanning parameters for reducing scan time.

methodsThis study was composed of a phantom study and two clinical tests. The differences in visual image quality scores, coefficient of variance (COV) of the background, image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and recovery coefficient (RC) of the sphere were compared between SSC mode and traditional Step-and-Shoot (SS) mode in the phantom study. Various "shoot" acquisition times (5s, 10s, 15s) and "step" angles (3-degree, 6-degree, 9-degree) were evaluated and verified. In the clinical tests, bone tomography and parathyroid tomography were performed on 30 patients each. Differences in visual image quality scores, background COV, image SNR, CNR, and standardized uptake value (SUV) of lesions were compared between the two modes.

resultsIn the phantom study, SSC mode demonstrated higher visual scores and significantly reduced background COV (P < 0.05), and significantly increased SNR and CNR (P < 0.05) compared to SS mode. No significant alteration in RC was observed (P > 0.05). In the clinical tests, no significant differences were found between the optimal SSC scan combination (10s "shoot" and 6-degree "step")/ (10s "shoot" and 3-degree "step") and the traditional SS scan combination (15s "shoot" and 6-degree "step")/ (15s "shoot" and 3-degree "step") in visual image quality scores, background COV, image SNR, CNR, and SUV of bone and parathyroid high uptake lesions (P > 0.05).

conclusionThe SwiftScan SSC mode can reduce acquisition time by 33% while maintaining similar image quality and quantification accuracy compared to SS mode. An SSC scanning protocol with a 10s "shoot" acquisition and 6-degree "step" or with a 10s "shoot" acquisition and 3-degree "step" over a 360-degree rotation, is recommended for clinical use.

Indexed as

Acquisition efficiencyImage qualitySPECT/CTStep-and-shoot continuous modeSwiftScan

Identifiers

PMID39745654
PMCPMC11695528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.