Evidence map›Paper›PMID 39745055›Full record

ArticleClinical chemistry and laboratory medicine2025

Comparative evaluation of peptide vs. protein-based calibration for quantification of cardiac troponin I using ID-LC-MS/MS.

Meltem Asicioglu, Claudia Swart, Evren Saban, Emrah Yurek, Nevin Gul Karaguler, Merve Oztug

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Clinical chemistry and laboratory medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Meltem Asicioglu70777 TUBITAK National Metrology Institute (TUBITAK UME) , Kocaeli, Türkiye.ORCID 0000-0002-2718-794X
Claudia SwartPhysikalisch-Technische Bundesanstalt, Braunschweig, Germany.ORCID 0000-0002-2347-196X
Evren Saban70777 TUBITAK National Metrology Institute (TUBITAK UME) , Kocaeli, Türkiye.ORCID 0000-0002-1968-1470
Emrah YurekKanuni Sultan Suleyman Training and Research Hospital, Istanbul, Türkiye.
Nevin Gul KaragulerDepartment of Molecular Biology and Genetics, Faculty of Science and Letters, Istanbul Technical University, Istanbul, Türkiye.ORCID 0000-0002-2300-9484
Merve Oztug70777 TUBITAK National Metrology Institute (TUBITAK UME) , Kocaeli, Türkiye.ORCID 0000-0002-6287-2774

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAn analytical protocol based on isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), which includes a peptide-based calibration strategy, was developed and validated for the determination of cardiac troponin I (cTnI) levels in clinical samples. Additionally, the developed method was compared with a protein-based calibration strategy, using cTnI serving as a model for low-abundant proteins. The aim is to evaluate new approaches for protein quantification in complex matrices, supporting the metrology community in implementing new methods and developing fit-for-purpose SI- traceable peptide or protein primary calibrators.

methodsTo establish traceability to SI units, peptide impurity correction amino acid analysis (PICAA) was conducted to determine the absolute content of signature peptides in the primary standards. Immunoaffinity enrichment was used to capture cTnI from human serum, with a comparison between microbeads and nanobeads to improve enrichment efficiency. Parallel reaction monitoring was used to monitor two signature peptides specific to cTnI. Various digestion parameters were optimized to achieve complete digestion.

resultsThe analytical method demonstrated selectivity and specificity, allowing the quantification of cTnI within 0.9-22.0 μg/L. The intermediate precision RSD was below 28.9 %, and the repeatability RSD was below 5.8 % at all concentration levels, with recovery rates ranging from 87 % to 121 %. The comparison of calibration strategies showed similar LOQ values, but the peptide-based calibration exhibited significant quantitative bias in recovery rates. The data are available via ProteomeXchange (PXD055104).

conclusionsThis isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method, based on peptide calibration, successfully quantified cTnI in human serum. Comparing this with protein-based calibration highlighted both the strengths and potential limitations of peptide-based strategies.

Indexed as

PeptidesTandem Mass SpectrometryTroponin ICalibrationChromatography, LiquidHumansLiquid Chromatography-Mass SpectrometryPeptidesTroponin IcTnIimmunoaffinity enrichmentisotope dilution mass spectrometry (ID-MS)magnetic particlespeptide-based calibrationpeptide impurity correction amino acid analysis (PICAA)

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.