Evidence map›Paper›PMID 39744073›Full record

ArticleBJUI compass2024

Accuracy of warm ischemia time measurement using a surgical intelligence software in partial nephrectomies: A validation study.

Archan Khandekar, Joao G Porto, Jean C Daher, Pedro F S Freitas, Dotan Asselman, Maritza M Suarez, Mark L Gonzalgo, Dipen J Parekh, Sanoj Punnen

Abstract read
In one paragraph

Article in BJUI compass, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Artificial intelligence in urology training Enhancing annotation, feedback, and evaluation in robotic, laparoscopic, and endoscopic surgery.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2026
    Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Archan KhandekarDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Joao G PortoDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.ORCID https://orcid.org/0000-0002-6495-1054
Jean C DaherDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Pedro F S FreitasDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Dotan AsselmanTheator Inc. Palo Alto California USA.
Maritza M SuarezDepartment of Medicine University of Miami Miller School of Medicine Miami Florida USA.
Mark L GonzalgoDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Dipen J ParekhDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Sanoj PunnenDesai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The objectives of this study are to compare the accuracy of warm ischemia times (WITs) derived by a surgical artificial intelligence (AI) software to those documented in surgeon operative reports during partial nephrectomy procedures and to assess the potential of this technology in evaluating postoperative renal function. Patients and methods: A surgical AI software (Theator Inc., Palo Alto, CA) was used to capture and analyse videos of partial nephrectomies performed between October 2023 and April 2024. The platform utilized computer vision algorithms to detect clamp placement and removal, enabling precise WIT measurement. Expert-reviewed surgical videos served as the ground truth. Platform-derived WITs were compared to those in surgeon operative reports using paired-sample Results: Of 64 eligible cases, 61 were included in the final analysis. Platform-derived WITs were within 1 min of the ground truth in all procedures, within 30 s in 97%, and within 10 s in over 80%. The mean difference between platform-derived WITs and ground truth was 8.3 s, significantly lower than the 2.45 min difference for operative reports ( Conclusion: This study demonstrates the high accuracy of a surgical intelligence platform in measuring WIT during partial nephrectomies. The findings support the use of AI-based surgical time measurement for precise intraoperative documentation and highlight the potential of integrating these data with EHRs to advance research on surgical outcomes.

Indexed as

artificial intelligencecomputer visionpartial nephrectomyrenal tumourwarm ischemia time

Identifiers

PMID39744073
PMCPMC11685170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.