ArticleEuropean radiology2025
Implementing an AI algorithm in the clinical setting: a case study for the accuracy paradox.
Article in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Diagnostic accuracy & clinical importance of AI confidence for extremity fracture detection: 2,508-patient retrospective cohort.Emergency radiology · 2026Article
- A Detection, Diagnostic, and Triage AI Buyer's Guide: Questions that Matter.Journal of imaging informatics in medicine · 2026Article
- Observational
- Radiologist Perceptions of an AI Tool for Intracranial Hemorrhage Detection in Teleradiology: Cross-Sectional Survey Study.JMIR human factors · 2026Article
- Letter to the Editor: Radiologist burnout-AI's true black box.European radiology · 2026Article
- Machine-learning algorithms for detecting intracranial hemorrhage on head computed tomography.The Cochrane database of systematic reviews · 2026Article
- A novel statistical framework for quantifying risks and benefits of AI automation in screening mammography.PLOS digital health · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesWe report our experience implementing an algorithm for the detection of large vessel occlusion (LVO) for suspected stroke in the emergency setting, including its performance, and offer an explanation as to why it was poorly received by radiologists. MATERIALS AND
methodsAn algorithm was deployed in the emergency room at a single tertiary care hospital for the detection of LVO on CT angiography (CTA) between September 1st-27th, 2021. A retrospective analysis of the algorithm's accuracy was performed.
resultsDuring the study period, 48 patients underwent CTA examination in the emergency department to evaluate for emergent LVO, with 2 positive cases (60.3 years ± 18.2; 32 women). The LVO algorithm demonstrated a sensitivity and specificity of 100% and 92%, respectively. While the sensitivity of the algorithm at our institution was even higher than the manufacturer's reported values, the false discovery rate was 67%, leading to the perception that the algorithm was inaccurate. In addition, the positive predictive value at our institution was 33% compared with the manufacturer's reported values of 95-98%. This disparity can be attributed to differences in disease prevalence of 4.1% at our institution compared with 45.0-62.2% from the manufacturer's reported values.
conclusionDespite the LVO algorithm's accuracy performing as advertised, it was perceived as inaccurate due to more false positives than anticipated and was removed from clinical practice. This was likely due to a cognitive bias called the accuracy paradox. To mitigate the accuracy paradox, radiologists should be presented with metrics based on a disease prevalence similar to their practice when evaluating and utilizing artificial intelligence tools. KEY POINTS: Question An artificial intelligence algorithm for detecting emergent LVOs was implemented in an emergency department, but it was perceived to be inaccurate. Findings Although the algorithm's accuracy was both high and as advertised, the algorithm demonstrated a high false discovery rate. Clinical relevance The misperception of the algorithm's inaccuracy was likely due to a special case of the base rate fallacy-the accuracy paradox. Equipping radiologists with an algorithm's false discovery rate based on local prevalence will ensure realistic expectations for real-world performance.
Indexed as
Identifiers
39741216What OpenQuestion holds
Registered trials