ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024
A tension system for angular correction of bent intramedullary nails: in vitro analysis.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeAlthough several techniques have been described for bent intramedullary nail removal, there is no universally accepted strategy. We hypothesized that a device based on the action principle of a three-point bend fixture could facilitate extraction of bent intramedullary nails; this paper describes its design and experimental testing.
methodsFive large synthetic left femurs and five steel intramedullary nails were used. The nails were bent in a manual hydraulic press and implanted into the model femurs, which had been previously sectioned as necessary. A device to correct the angular deformity imparted to the nails was designed, and a prototype fabricated from AISI 1045 steel. Specimens were secured in a vise and the device attached; manual tension was then applied to gradually correct the nail deformity. Plain radiographs were obtained, and the nails were removed. The model femurs and intramedullary nails were visually inspected for proper contact of the device tip, coronal and sagittal alignment, and points of failure.
resultsBefore device application, the angles of the specimens averaged 40.2° (38.27°-41.32°) in the coronal plane and 7.22° (8.5°-10.2°) in the sagittal plane. After device application, these angles averaged 15.04° (2.5°-32.3°) and 4.16° (0°-9.8°), respectively. There were no implant fractures, but in two models, peri-implant fractures (one catastrophic) occurred close to the proximal and distal locking screws.
conclusionThe proposed device for bent intramedullary nail extraction was effective, but homogeneous behavior in terms of angle correction was not observed in the tested specimens. Further development is needed.