ReviewNature protocols2025
A guide to building a low-cost centrifuge force microscope module for single-molecule force experiments.
Review in Nature protocols, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- A 3D Printed Mini-Gel Electrophoresis System for Rapid and Inexpensive DNA Nanoswitch Biosensing.ACS measurement science au · 2026Article
- Beyond the Single Molecule: Multiplexed Methods in Force Spectroscopy.Annual review of biophysics · 2026Review
- A 3D printed mini-gel electrophoresis system for rapid and inexpensive DNA nanoswitch biosensing.bioRxiv : the preprint server for biology · 2026Article
- Investigating Polarity Effects in DNA Base Stacking.JACS Au · 2025Article
- Probing the Dynamic Strength of Biomolecular Interactions with Single-Cell Centrifugation.ACS central science · 2025Article
- Tuning the Stability of DNA Tetrahedra with Base Stacking Interactions.Nano letters · 2025Article
- High-Throughput Centrifuge Force Microscopy Reveals Dynamic Immune-Cell Avidity at the Single-Cell Level.bioRxiv : the preprint server for biology · 2025Article
- Tuning the stability of DNA tetrahedra with base-stacking interactions.bioRxiv : the preprint server for biology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
The ability to apply controlled forces to individual molecules or molecular complexes and observe their behaviors has led to many important discoveries in biology. Instruments capable of probing single-molecule forces typically cost >US$100,000, limiting the use of these techniques. The centrifuge force microscope (CFM) is a low-cost and easy-to-use instrument that enables high-throughput single-molecule studies. By combining the imaging capabilities of a microscope with the force application of a centrifuge, the CFM enables the simultaneous probing of hundreds to thousands of single-molecule interactions using tethered particles. Here we present a comprehensive set of instructions for building a CFM module that fits within a commercial benchtop centrifuge. The CFM module uses a 3D-printed housing, relies on off-the-shelf optical and electrical components, and can be built for less than US$1,000 in about 1 day. We also provide detailed instructions for setting up and running an experiment to measure force-dependent shearing of a short DNA duplex, as well as the software for CFM control and data analysis. The protocol is suitable for users with basic experience in analytical biochemistry and biophysics. The protocol enables the use of CFM-based experiments and may facilitate access to the single-molecule research field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.