ArticleScientific reports2024
Energy and exergy analysis of a modified air handling unit assisted by phase change material, heat recovery unit, and solar energy.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This research focuses on designing an energy storage system using phase change material (PCM) in the air-conditioned zone, integrated with an air handling unit (AHU). The proposed system introduces a novel approach to reducing energy consumption in buildings by incorporating a solar heating coil and PCM. Through detailed energy and exergy analyses, the study evaluates the AHU's performance and optimises the thickness and position of the PCM layer using genetic algorithm (GA) optimisation. Simulation of the proposed system was conducted using ASPEN Hysys and MATLAB software. Results demonstrate that integrating PCM reduces heat exchange by 687 kWh and optimising the PCM layer further improves system efficiency. Implementing a solar system decreases irreversibility by 7.3% compared to an AHU without solar integration, with a more significant reduction of 12.49% observed during hot months. Overall, the total irreversibility is reduced by 8%, with the solar system contributing to 80.6% of the irreversibility. These findings highlight the combined effect of PCM optimisation and solar integration in enhancing the energy and exergy performance of AHU systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.