Evidence map›Paper›PMID 39738459›Full record

ArticleScientific reports2024

Characteristics and factors associated with diameter deviation of rhexis reference circle generated by an image-guided system in cataract surgery: a cross-sectional study.

Yabo Fu, Yulong Huang, Xiaobao Liu, Chishan Kang, Wenjie Wu, Qiong Li

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yabo Fu *Department of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, 134 East Street, Fuzhou, 350000, People's Republic of China.
Yulong Huang *Provincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People's Republic of China.
Xiaobao LiuProvincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People's Republic of China.
Chishan KangProvincial Clinical Medical College of Fujian Medical University, Fujian Medical University, Fuzhou, People's Republic of China.
Wenjie WuDepartment of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, 134 East Street, Fuzhou, 350000, People's Republic of China. wenjie_wu@foxmail.com.
Qiong LiDepartment of Ophthalmology, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, 134 East Street, Fuzhou, 350000, People's Republic of China. liqiong2000@hotmail.com.

Funding

Natural Science Foundation of Fujian Province 2022J011006the Medical Innovation Program of Fujian Province 2023CXA001
6 · The paper itself

Abstract

More attention should be paid to the deviations between the actual diameter of the rhexis reference circle which projected by the Image-guided systems and its intended size, and assess the influence of ocular biometric parameters on the deviation. In this study, the Callisto eye image-guided system was employed to generate a digital rhexis reference circle (rhexis overlay) set at an intended diameter of 6 mm and a screenshot of the video was taken at the end of the cataract surgery, then to compare the deviation between the observed rhexis overlay diameter (ROD) and the optic diameter (6 mm). The factors influencing diameter deviation were identified with univariate and multivariate linear regression. Subgroup analyses were conducted based on factors identified in the multivariate regression. And we observed that a total of 213 eyes of 174 patients were included in the final analysis. The diameter deviation averaged - 0.24 ± 0.28 mm (P = 0.0001) and was positively correlated with phakic anterior chamber depth (ACD) (P < 0.001) and negatively correlated with white-to-white (WTW) measurement (P < 0.001). Subgroup analyses revealed significantly greater diameter deviation in cases with preoperative ACD < 2.5 mm and WTW ≥ 12.0 mm (all P < 0.05). Following optimization, the mean diameter deviation was 0.00047 ± 0.26 mm (P > 0.05). In conclusion, the Callisto eye image-guided system demonstrates good precision in CCC assistance. However, there remains a slight deviation from the intended size when generating the rhexis reference circle in eyes with shallow anterior chambers and larger corneas. Implementing an optimization process could be beneficial for these eyes.

Indexed as

Cataract ExtractionSurgery, Computer-AssistedAgedAged, 80 and overAnterior ChamberCataractCross-Sectional StudiesFemaleHumansMaleMiddle AgedCapsulorhexisDeviationImage-guided systemThe influencing factor

Identifiers

PMID39738459
PMCPMC11686302

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.