Evidence map›Paper›PMID 39737605›Full record

Observational studyArtificial organs2025

Perfusion Pressures and Weight Loss During Normothermic Machine Perfusion of Human Donor Livers.

Bianca Lascaris, Silke B Bodewes, Adam M Thorne, Marius C van den Heuvel, Robbert J de Haas, Maarten W N Nijsten, Vincent E de Meijer, Robert J Porte

Abstract readObservational Study
In one paragraph

Observational study in Artificial organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Bianca LascarisDepartment of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0003-0258-1112
Silke B BodewesDepartment of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0001-6137-4901
Adam M ThorneDepartment of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0001-5550-2364
Marius C van den HeuvelDepartment of Pathology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0001-6985-7107
Robbert J de HaasDepartment of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0002-4915-6781
Maarten W N NijstenDepartment of Critical Care, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0002-0981-9392
Vincent E de MeijerDepartment of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0002-7900-5917
Robert J PorteDepartment of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID https://orcid.org/0000-0003-0538-734X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNormothermic machine perfusion (NMP) is increasingly used to preserve and assess donor livers prior to transplantation. Due to its success, it is expected that more centers will start using this technology. However, NMP may also cause adverse effects.

methodsIn this retrospective, observational study, we investigated the effect of NMP pressures on donor liver weight, post-transplant outcomes, and hepatic perfusion characteristics. A total of 36 livers were transplanted after NMP. NMP perfusion pressure settings were lowered from a median (IQR) of 47 mmHg (42-54) to 34 mmHg (30-39) for the hepatic artery (HA), and from 8 mmHg (7-10) to 7 mmHg (6-8) for the portal vein (PV) to diminish potential edema formation inside the liver.

resultsThis change appeared to lead to a reduction of liver weight after NMP (-22 g to -143 g, p = 0.02), without affecting the PV flow velocity (35.5 to 48.0 cm/s, p = 0.54), or hepatocellular injury markers during NMP (AST 1511-1148 U/L, p = 0.44; ALT 318-849 U/L, p = 0.35), and post-transplantation outcomes. Changes in liver weight correlated significantly with the applied PV pressure during NMP (r = 0.52, p < 0.01) and the HA flow (r = 0.38, p < 0.05).

conclusionNMP can lead to a reduction in liver weight, which might be masked by edema when high perfusion pressures are used. We encourage applying the lowest perfusion pressures possible to reach adequate flows and oxygen supply during liver NMP.

Indexed as

LiverLiver TransplantationOrgan PreservationPerfusionWeight LossAdultFemaleHepatic ArteryHumansMaleMiddle AgedOrgan SizePortal VeinPressureRetrospective StudiesTissue Donorsedemalivernormothermic machine perfusiontransplantation

Identifiers

PMID39737605
PMCPMC12019101

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.