Evidence map›Paper›PMID 39735057›Full record

ArticleCureus2024

Pedicle Screw Pull-Out Strength Between the Jamshidi Needle and Pedicle Probe Techniques in an Osteoporotic Cancellous Bone Model: A Biomechanical Study.

Shival Tharmaseelan, Mohd Hezery Harun, Fadzrul Abbas Mohamed Ramlee, Mohd Na'im Abdullah

Abstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Shival TharmaseelanOrthopaedics and Traumatology, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Mohd Hezery HarunOrthopaedics and Traumatology, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Fadzrul Abbas Mohamed RamleeOrthopaedics and Traumatology, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Mohd Na'im AbdullahAerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques. The research sought to determine if the surgical device used in aiding pedicle screw placement, pedicle probe (open technique) and Jamshidi needle (minimally invasive surgical (MIS) technique), affects the eventual stability of the screw in osteoporotic conditions. The findings of this study could enlighten surgical practices, potentially leading to improved clinical outcomes for patients suffering from osteoporosis-related spinal instability. Materials and methods An in vitro biomechanical comparative study was performed whereby pedicle screws were inserted into a standardized polyurethane foam model of grade 10, mimicking osteoporotic bone. Cylindrical poly-axial pedicle screws of 6.5 mm diameter and 45 mm length made out of medical-grade titanium alloy, Ti-6Al-4V, were inserted using four different techniques: Jamshidi needle, Jamshidi needle with tapping, pedicle probe, and pedicle probe with tapping. The screws were inserted in a standardized manner across all groups; the constructs were subsequently attached to the Material Testing System (MTS) 810 machine (MTS Systems Corporation, Eden Prairie, Minnesota, United States) using a customized jig. A direct-load-to-fail test was performed, where data was collected and tabulated into a force-displacement graph. The axial pull-out strength, axial stiffness, and displacement to failure of each construct were then extracted from the graph. Independent samples t-test was then used to compare and study the association between the groups. Results The pedicle probe technique demonstrated superior pull-out strength (698.36±16.34 N) compared to the Jamshidi needle technique (557.15±4.52N) (p<0.05). A greater displacement to failure was also seen in the pedicle probe group (2.26±0.04 mm) versus the Jamshidi needle group (1.18±0.06 mm) (p<0.05). However, the Jamshidi needle technique exhibited higher axial stiffness (336.88±23.24 N/mm) compared to the pedicle probe technique (208.82±7.82 N/mm) (p<0.05). In examining the influence of tapping on both techniques, results show significantly reduced pull-out strength and displacement to failure in the pedicle probe group. Conclusions The pedicle probe technique offers enhanced initial stability in the osteoporotic bone as evidenced by the superior pull-out strength and displacement to failure. On the other hand, the Jamshidi needle technique provides greater resistance to deformation, demonstrated by higher axial stiffness. Tapping should be carefully considered, especially while using the pedicle probe technique, as demonstrated by significantly reduced pull-out strength and displacement to failure. The choice of technique should be informed by specific clinical context balancing the need for initial stability, resistance to deformation, and risk of screw failure.

Indexed as

biomechanical modeljamshidi needlepedicle probes: osteoporosisspinal fusion surgery

Identifiers

PMID39735057
PMCPMC11682839

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.