Dosimetric Evaluation of Different Algorithms on Heterogeneous Slab Phantom Using CMS XiO and MONACO Treatment Planning System for 4MV, 6MV and 15MV Beam Energy: An Institutional Study.

Ajay Katake, Lalit Kumar, Balbir Singh, Nijun Mishra, Pradeep Gurjar, Rajesh Vashistha, Deepak Basandrai

Abstract read
In one paragraph

Article in Asian Pacific journal of cancer prevention : APJCP, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ajay KatakeDepartment of Physics, Lovely Professional University, Phagwara, India.
Lalit KumarDepartment of Radiation Oncology, Max Super speciality Hospital, Saket, India.ORCID 0000-0001-7753-253X
Balbir SinghDepartment of Radiation Oncology, SLBSGMC & H, Nerchowk, Mandi, India.ORCID 0000-0003-1818-5851
Nijun MishraDepartment of Radiation Oncology, GCRI-BCCRI, Bhavnagar, India.
Pradeep GurjarDepartment of Radiation Oncology, Max Super Speciality Hospital, Bathinda, India.
Rajesh VashisthaDepartment of Radiation Oncology, Max Super Speciality Hospital, Bathinda, India.ORCID 0000-0001-6898-2440
Deepak BasandraiDepartment of Physics, Lovely Professional University, Phagwara, India.ORCID 0000-0001-5762-4648

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies. MATERIAL AND

methodsStyrofoam blocks of thickness 1.90 cm, 3.8 cm and 5.70 cm was used to introduce inhomogeneity in a slab phantom. Wipro GE computed tomography (CT) scanner was used to scan the phantom. Doses were computed on the central axis of the beam using convolution (C), superposition (S), fast superposition (FS), collapsed cone convolution (CCC) and monte carlo (MC) algorithms for field geometries of 5x5 cm2 and 10x10 cm2 for above said photon beam energies, respectively. An Ion chamber (IC) of 0.6 cc volume was used for the dose measurements. The deviation between measured and TPS computed doses were recorded.

resultsThe PDD (Percentage depth dose) data obtained from the TPS (calculated data) and LINAC (measured data) was used for comparison based on different algorithms in order to calculate the percentage of maximum deviation (PMD). The PMD in MC algorithm were calculated for field sizes of 5x5 cm2 and 10x10 cm2 are found to be in ranging from 0.73% to -4.49% for 4MV,  1.62% to -2.42% for 6MV and 4.53% to -1.47%  for 15 MV for 1.90 cm air gap, 2.21% to -3.75% for 4MV, 3.87% to -2.88% for 6 MV and 4.87% to -3.46%  for 15 MV for 3.80 cm air gap, 2.77% to -4.66% for 4MV, 3.87% to -2.86% for 6 MV and 5.66% to -4.92% for 15 MV for 5.70cm air gap which is less as compared to CCC, C, FS, and S algorithms.

conclusionThe comparison of C, S, FS, CCC and MC algorithms demonstrated that MC having better agreement with IC measurements. In conclusion, MC is a superior option for dose computation, particularly in the presence of low-density heterogeneities.

Indexed as

AlgorithmsMonte Carlo MethodPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedHumansParticle AcceleratorsPhotonsRadiometryRadiotherapy, Intensity-ModulatedTomography, X-Ray ComputedAir gapKeywords:- Monte Carlophantom and heterogeneity

Identifiers

PMID39733431
PMCPMC12008326

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.