ArticleScientific reports2024
Detection of Mycobacterium chimaera in medical device water samples by customised real time PCR using a InGenius platform.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Mycobacterium chimaera, belonging to the Mycobacterium avium complex, is an opportunistic environmental mycobacterium which has been isolated from medical device water samples such as Heater Cooler Units (HCU). Laboratories currently use culture-based diagnostic methods to detect M. chimaera, but these take a long time to obtain results. The aim of this study is to test and define the Limit of Detection (LoD) of a Real-Time Polymerase Chain Reaction test (RT-PCR) specific for M. chimaera, using a sample-to-result InGenius platform, performed on medical device water samples collected at the referral centre for the detection of mycobacteria from environmental specimens of Bologna, Italy. A total of 285 water samples were included in this study. The sensitivity and specificity of RT-PCR compared to culture were 60.5% and 98.8% respectively, with an overall agreement of 82.1% and a positive predictive value of 97.4%. The LoD calculated was approximately 2900 CFU/ml. In conclusion, this study confirmed that detection of M. chimaera with RT-PCR could support culture-based methods in reducing the time necessary to identify highly colonised HCUs, with high positive predictive values. Therefore, we suggest performing this customised RT-PCR on concentrated decontaminated water samples, shutting down and thoroughly disinfecting positive HCUs, to reduce the risk of patient infection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.