Evidence map›Paper›PMID 39730439›Full record

ArticleScientific reports2024

Accuracy of breast ultrasound image analysis software in feature analysis: a comparative study with sonographers.

Zuxin Wang, Chen Xu, Jun Zhou, Ying Wang, Zhongqing Xu, Fan Hu, Yong Cai

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zuxin Wang *Department of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China.
Chen Xu *Department of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China.
Jun ZhouProject Department, Tend.AI Medical Technologies Co., Ltd, Shanghai, China.
Ying WangDepartment of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China.
Zhongqing XuDepartment of General Practice, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Fan HuDepartment of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China. hufan@sjtu.edu.cn.
Yong CaiDepartment of Public Health, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, 1111 Xianxia Road, Shanghai, 200335, China. caiyong202028@hotmail.com.

Funding

Clinical Research Project of Shanghai Municipal Health Commission 202240198Key Discipline Projects of Shanghai Three-Year Action Plan for Public Health under Grant GWVI-11.1-29Key Supporting Disciplines of Shanghai Health System Grant Number-2023ZDFC0403Science and Technology Commission Shanghai Municipality Grant 20JC1410204Shanghai Health Care Commission Clinical Research Program 20214Y0205
6 · The paper itself

Abstract

Breast ultrasound is recommended for early breast cancer detection in China, but the rapid increase in imaging data burdens sonographers. This study evaluated the agreement between artificial intelligence (AI) software and sonographers in analyzing breast nodule features. Breast ultrasound images from two hospitals in Shanghai were analyzed by both the software and the sonographers for features including echotexture, echo pattern, orientation, shape, margin, calcification, and posterior echo attenuation. Agreement between software and sonographers was compared using the proportion of agreement and Kappa, with analysis time also evaluated. A total of 493 images were analyzed. The proportion of agreement between software and sonographers in assessing features was 80.5% for echotexture, 84.4% for echo pattern, 93.7% for orientation, 85.8% for shape, 88.6% for margin, 80.5% for calcification, and 90.5% for posterior echo attenuation, highlighting software's high accuracy. Cohen's kappa for other features indicated moderate to substantial agreement (0.411-0.674), with calcification showing fair agreement (0.335). The software significantly reduced analysis time compared to sonographers (P < 0.001). The software showed high accuracy and time efficiency. AI software presents a viable solution for reducing sonographers' workload and enhance healthcare in underserved areas by automating feature analysis in breast ultrasound images.

Indexed as

Breast NeoplasmsSoftwareUltrasonography, MammaryAdultAgedArtificial IntelligenceChinaFemaleHumansImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMiddle AgedArtificial intelligenceBreast cancerComparative studyProportion of agreementUltrasound

Identifiers

PMID39730439
PMCPMC11681128

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.