Evidence map›Paper›PMID 39727866›Full record

ArticleBiosensors2024

Widening of Dynamic Detection Range in Real-Time Angular-Interrogation Surface Plasmon Resonance Biosensor Based on Anisotropic Van Der Waals Heterojunction.

Xiantong Yu, Jing Ouyang, Zhao Li, Chaojun Shi, Longfei Wang, Jun Zhou, Min Chang

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiantong YuKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Jing OuyangKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Zhao LiKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Chaojun ShiKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Longfei WangKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Jun ZhouKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Min ChangKey Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.

Funding

National Key Research and Development Program of China 2021YFF0600902
6 · The paper itself

Abstract

Surface plasmon resonance (SPR) biosensors have experienced rapid development in recent years and have been widely applied in various fields. Angular-interrogation SPR biosensors play an important role in the field of biological detection due to their advantages of reliable results and high stability. However, angular-interrogation SPR biosensors also suffer from low detection sensitivity, poor real-time performance, and limited dynamic detection range, which seriously restricts their application and promotion. Therefore, we designed an angular-interrogation SPR biosensor based on black phosphorus (BP)/graphene two-dimensional (2D) van der Waals heterojunction (vdWhs). On the basis of using the angle-fixed method, this biosensor not only has good real-time performance but also detection sensitivity enhancement. The optical anisotropy characteristic of BP is used to widen the dynamic detection range of biosensors. The simulation results show that the maximum detection sensitivity of the proposed biosensor is 258.6 deg/RIU. Compared with the bare-Ag film structure biosensor, the detection sensitivity was enhanced by 209.2% by 2D vdWhs. The use of anisotropic 2D material BP can not only enhance the detection sensitivity but also widen the detection range. When the fixed incident angle is

Indexed as

Biosensing TechniquesSurface Plasmon ResonanceAnisotropyGraphitePhosphorusGraphitePhosphorusangular-interrogation surface plasmon resonance (SPR) sensorblack phosphorus (BP)dynamic detection rangetwo-dimensional (2D) van der Waals heterojunction (vdWhs)

Identifiers

PMID39727866
PMCPMC11674669

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.