ArticleBiomimetics (Basel, Switzerland)2024
Optical Flow Sensor with Fluorescent-Conjugated Hyperelastic Pillar: A Biomimetic Approach.
Article in Biomimetics (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Although the Doppler velocity log is widely applied to measure underwater fluid flow, it requires high power and is inappropriate for measuring low flow velocity. This study proposes a fluid flow sensor that utilizes optical flow sensing. The proposed sensor mimics the neuromast of a fish by attaching a phosphor to two pillar structures (A and B) produced using ethylene propylene diene monomer rubber. The optical signal emitted by the phosphor is measured using a camera. An experiment was conducted to apply an external force to the reactive part using a push-pull force gauge sensor to confirm the performance of the proposed sensor. The optical signal emitted by the phosphor was obtained using an image sensor, and a quantitative value was calculated using image analysis. A simulation environment was constructed to analyze the flow field and derive the relationship between the flow rate and velocity. The physical properties of the pillar were derived from hysteresis measurement results, and the error was minimized when pillar types A and B were utilized within the ranges of 0-0.1 N and 0-2 N, respectively. A difference in the elastic recovery characteristics was observed; this difference was linear based on the shape of the pillar, and improvement rates of 99.585% and 99.825% were achieved for types A and B, respectively. The proposed sensor can help obtain important information, such as precise flow velocity measurements in the near field, to precisely navigate underwater unmanned undersea vehicles and precisely control underwater robots after applying the technology to the surface of various underwater systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.