Evidence map›Paper›PMID 39724217›Full record

ArticlePloS one2024

Effect of curing temperature freeze-thaw failure mechanism and damage model of equal-strength air-entrained concrete.

YongHe Liu, Bo Yang, Aojun Guo

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

YongHe LiuCivil Engineering Department, Lanzhou Jiaotong University, Lanzhou, China.
Bo YangCivil Engineering Department, Lanzhou Jiaotong University, Lanzhou, China.ORCID 0009-0004-7389-433X
Aojun GuoCivil Engineering Department, Lanzhou Jiaotong University, Lanzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Belt and Road strategy has significantly advanced the scale of infrastructure construction in the Qinghai-Tibet Plateau permafrost area. Consequently, this demands higher requirements on the strength and frost resistance of concrete (FRC) cured under low-temperature and negative-temperature conditions. Accordingly, in this study, tests on the mechanical properties and FRC were conducted under standard curing, 5 °C curing, and -3 °C curing conditions. The pore structure characteristics of concrete subjected to freeze-thaw (F-T) damage (FTD) under different curing methods were analyzed using nuclear magnetic resonance. The study results show that when the air content is constant, the compressive strength of concrete (CSC) tends to decrease with the curing temperature. Moreover, the occurrence of an age lag phenomenon is evident. The compressive strength of concrete cured under standard curing for 28-d was comparable to that achieved by concrete cured at 5 °C curing for 56-d and at -3 °C curing for 84-d. Under the same curing conditions, the CSC decreases with increasing air content. Observations revealed that with the air content in the concrete set at 0.08%, the material's compressive strength was at its minimum. As the number of F-T cycles increases, the concrete transverse relaxation time (T2) curve shifts to the right, and the proportion of both harmful and multi-harmful pores increases. Based on the same CSC under different curing methods, the FRC under 5 °C curing and -3 °C curing conditions is considerably lower than that under standard curing conditions. Moreover, the FRC exhibits an increasing and then a decreasing trend with increasing air content. Concrete exhibits the best frost resistance when the air content is 3.6%. It was established that an optimal range exists for air content in concrete. If the air content is too low, there is only a slight improvement in the FRC. Conversely, if the air content was excessively high, it leads to a significant decrease in frost resistance. Further, this study establishes an FTD model for concrete under 5 °C curing and -3 °C curing conditions considering the compressive strength factors of concrete under standard curing conditions for 28-d. This study is anticipated to be used as reference for determining the FRC cured under different temperatures.

Indexed as

Compressive StrengthConstruction MaterialsFreezingAirMaterials TestingTemperature

Identifiers

PMID39724217
PMCPMC11671025

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.