Evidence map›Paper›PMID 39721994›Full record

ArticleInternational journal for numerical methods in biomedical engineering2025

Fluid-Structure Interaction Analysis of Trapezoidal and Arc-Shaped Membranes Mimicking the Organ of Corti.

Kentaro Doi, Sho Takeuchi, Hiroki Yamazaki, Tetsuro Tsuji, Satoyuki Kawano

Abstract read
In one paragraph

Article in International journal for numerical methods in biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kentaro DoiDepartment of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.ORCID https://orcid.org/0000-0002-2663-9369
Sho TakeuchiDepartment of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.
Hiroki YamazakiDepartment of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.ORCID https://orcid.org/0000-0003-1573-8940
Tetsuro TsujiDepartment of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.ORCID https://orcid.org/0000-0002-2087-5459
Satoyuki KawanoDepartment of Mechanical Science and Bioengineering, Graduate School of Engineering Science, Osaka University, Osaka, Japan.

Funding

Japan Agency for Medical Research and DevelopmentJapan Society for the Promotion of Science
6 · The paper itself

Abstract

In a previous study [H. Shintaku et al., Sensors and Actuators A: Physical 158 (2010): 183-192], an artificially developed auditory sensor device showed a frequency selectivity in the range from 6.6 to 19.8 kHz in air and from 1.4 to 4.9 kHz in liquid. Furthermore, the sensor succeeded in obtaining auditory brain-stem responses in deafened guinea pigs [T. Inaoka et al., Proceedings of the National Academy of Sciences of the United States of America 108 (2011): 18390-18395]. Since then, several research groups have developed piezoelectric auditory devices that have the capability of acoustic/electric conversion. However, the piezoelectric devices are required to be optimally designed with respect to the frequency range in liquids. In the present study, focusing on the trapezoidal shape of the piezoelectric membrane, the vibration characteristics are numerically and experimentally investigated. In the numerical analysis, solving a three-dimensional fluid-structure interaction problem, resonant frequencies of the trapezoidal membrane are evaluated. Herein, Young's modulus of the membrane, which is made of polyvinylidene difluoride and is different from that of bulk, is properly determined to reproduce the experimental results measured in air. Using the modified elastic modulus for the membrane, the vibration modes and resonant frequencies in liquid are in good agreement with experimental results. It is also found that the resonant characteristics of the artificial basilar membrane for guinea pigs are quantitatively reproduced, considering the fluid-structure interaction. The present numerical method predicts experimental results and is available to improve the frequency selectivity of the piezoelectric membranes for artificial cochlear devices.

Indexed as

Organ of CortiAnimalsElastic ModulusGuinea PigsMembranes, ArtificialVibrationMembranes, Artificialanimal testartificial basilar membranefluid–structure interactionPVDFresonant frequencyRinger's solution

Identifiers

PMID39721994
PMCPMC11669623

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.