ReviewExpert review of medical devices2025
Proactive esophageal cooling during radiofrequency cardiac ablation: data update including applications in very high-power short duration ablation.
Review in Expert review of medical devices, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Severe Esophageal Complications Following Atrial Fibrillation Ablation: Should We Still Be Concerned?Arquivos brasileiros de cardiologia · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
introductionProactive esophageal cooling reduces injury during radiofrequency (RF) ablation of the left atrium (LA) for the treatment of atrial fibrillation (AF). New catheters are capable of higher wattage settings up to 90 W (very high-power short duration, vHPSD) for 4 s. Varying power and duration, however, does not eliminate the risk of thermal injury. Furthermore, alternative energy sources such as pulsed field ablation (PFA) also exhibit thermal effects, with clinical data showing esophageal temperatures up to 40.3°C. The ensoETM esophageal cooling device (Attune Medical, now a part of Haemonetics, Boston, MA, U.S.A.) is commercially available and FDA-cleared to reduce thermal injury to the esophagus during RF ablation for AF and is recommended in the 2024 expert consensus statement on catheter and surgical ablation of AF. AREAS COVERED: This review summarizes growing evidence of esophageal cooling during high power RF ablation for AF treatment, including data relating to procedural efficacy, safety, and efficiency, and techniques to enhance operator success while providing directions for further research. EXPERT OPINION: Proactive esophageal cooling reduces injury to the esophagus during high power RF ablation, and utilizing this approach may result in increased success in first-pass isolation, procedural efficiency, and long-term efficacy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.