Evidence map›Paper›PMID 39720754›Full record

ArticleHealthcare technology letters2024

AR-assisted surgery: Precision placement of patient specific hip implants based on 3D printed PSIs.

Amaia Iribar-Zabala, Tanya Fernández-Fernández, Javier Orozco-Martínez, José Calvo-Haro, Rubén Pérez-Mañanes, Elena Aguilera-Jiménez, Carla de Gregorio-Bermejo, Rafael Benito, Alicia Pose-Díez-de-la-Lastra, Andoni Beristain-Iraola and 2 more

Abstract read
In one paragraph

Article in Healthcare technology letters, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Amaia Iribar-ZabalaDigital Health and Biomedical Technologies, Vicomtech Foundation Basque Research and Technology Alliance (BRTA) Donostia-San Sebastian Spain.ORCID https://orcid.org/0009-0000-4445-6622
Tanya Fernández-FernándezServicio de Cirugía Ortopédica y Traumatología Hospital General Universitario Gregorio Marañón Madrid Spain.
Javier Orozco-MartínezServicio de Cirugía Ortopédica y Traumatología Hospital General Universitario Gregorio Marañón Madrid Spain.
José Calvo-HaroServicio de Cirugía Ortopédica y Traumatología Hospital General Universitario Gregorio Marañón Madrid Spain.
Rubén Pérez-MañanesServicio de Cirugía Ortopédica y Traumatología Hospital General Universitario Gregorio Marañón Madrid Spain.
Elena Aguilera-JiménezInstituto de Investigación Sanitaria Gregorio Marañón Madrid Spain.
Carla de Gregorio-BermejoInstituto de Investigación Sanitaria Gregorio Marañón Madrid Spain.
Rafael BenitoDigital Health and Biomedical Technologies, Vicomtech Foundation Basque Research and Technology Alliance (BRTA) Donostia-San Sebastian Spain.
Alicia Pose-Díez-de-la-LastraDepartamento de Bioingeniería Universidad Carlos III de Madrid Leganés Spain.
Andoni Beristain-IraolaDigital Health and Biomedical Technologies, Vicomtech Foundation Basque Research and Technology Alliance (BRTA) Donostia-San Sebastian Spain.
Javier PascauDepartamento de Bioingeniería Universidad Carlos III de Madrid Leganés Spain.
Mónica García-SevillaDepartamento de Bioingeniería Universidad Carlos III de Madrid Leganés Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patient-specific implant placement in the case of pelvic tumour resection is usually a complex procedure, where the planned optimal position of the prosthesis may differ from the final location. This discrepancy arises from incorrect or differently executed bone resection and improper final positioning of the prosthesis. In order to overcome such mismatch, a navigation solution is presented based on an augmented reality application for HoloLens 2 to assist the entire procedure. This involves placing patient-specific instruments for tumour resection guidance in the supraacetabular, ischial and symphysial regions, performing the osteotomy and assisting within the adequate positioning of the implant. The supraacetabular patient-specific instrument and the prosthesis included optical markers attached to them to be used as reference for surgical guidance. The proposed application and workflow were validated by two clinicians on six phantoms, designed and fabricated from different cadaver specimens. The accuracy of the solution was evaluated by comparing the final position after navigation with the position defined in the surgical plan. Preliminary assessment shows promising results for the guidance system, with positive clinician feedback.

Indexed as

augmented realitybiomedical imagingcomputer visionholographyprostheticssurgerytracking

Identifiers

PMID39720754
PMCPMC11665800

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.