Evidence map›Paper›PMID 39719530›Full record

ArticleHypertension research : official journal of the Japanese Society of Hypertension2025

Validation of the Uscom BP+ automated oscillometric blood pressure monitor for professional office use in children and adolescents according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018).

Jonathan P Glenning, Freya Sheeran, Jodie Cuthbert, William Harris, Catherine Quinlan, Jonathan P Mynard

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Hypertension research : official journal of the Japanese Society of Hypertension, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Jonathan P GlenningHeart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia. jonathan.glenning@mcri.edu.au.
Freya SheeranHeart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
Jodie CuthbertHeart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
William HarrisHeart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.
Catherine QuinlanDepartment of Paediatrics, University of Melbourne, Parkville, VIC, Australia.
Jonathan P MynardHeart Research, Murdoch Children's Research Institute, Parkville, VIC, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To (1) assess the accuracy of the Uscom BP+ oscillometric upper-arm professional blood pressure (BP) monitor in children and adolescents as per the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018); (2) assess the suitability of a non-standard cuff; and (3) assess the impact of motion artefact on device accuracy and precision. Children and adolescents were recruited to fulfil the sex/cuff distribution criteria of the Universal Standard. Single arm sequential BP measurements were used, the test device measured on deflate with an altered child/adolescent algorithm, using three standard (Extra Small, Small Adult, Adult) and, as exploratory analysis, additionally in one non-standard cuff (Wide Range; WR) (arm circumferences: 12-17, 16-24, 22-32, 22-42 cm, respectively). The presence of motion artefact was determined and its impact on BP assessed. One-hundred-forty participants were recruited with 123 included for analysis. When using the Extra Small, Small Adult and Adult cuffs only, the BP+ passed both criteria (95 participants, 321 pairs, -0.1 ± 7.3/ - 1.6 ± 7.6 and 5.72/6.50 mmHg systolic/diastolic) (reference thresholds: ≤5 ± 8, ≤6.95/6.76, respectively). The inclusion of the WR cuff showed unacceptable imprecision, and motion artefact had a substantial influence on test device precision. The Uscom BP+ fulfilled the requirements of the Universal Standard in children and adolescents when using the altered algorithm with the three standard cuffs and can be recommended for clinical use. The WR cuff cannot be recommended in this population in measure-on-deflate mode due to its imprecision. Additionally, BP measurement accuracy in children and adolescents can be improved through inclusion of a motion artefact detection system.

Indexed as

Blood PressureBlood Pressure DeterminationBlood Pressure MonitorsOscillometryAdolescentChildFemaleHumansMaleBlood pressureBlood pressure determinationHumansPediatricsValidation studies as topic

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.