Evidence map›Paper›PMID 39717950›Full record

ArticlePacing and clinical electrophysiology : PACE2025

Value of P-wave Parameters in Predicting Outcomes of Repeat Catheter Ablation for Paroxysmal Atrial Fibrillation.

Ibrahim Antoun, Xin Li, Zakkariya Vali, Ivelin Koev, Riyaz Somani, G André Ng

Abstract read
In one paragraph

Article in Pacing and clinical electrophysiology : PACE, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ibrahim AntounDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.ORCID 0000-0002-4374-7476
Xin LiDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.
Zakkariya ValiDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.
Ivelin KoevDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.
Riyaz SomaniDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.
G André NgDepartment of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulmonary vein isolation (PVI) has been established as an effective management option for symptomatic paroxysmal atrial fibrillation (PAF). We aimed to explore the role of P-wave parameters in a 12-lead electrocardiogram (ECG) in predicting the success of repeat PAF ablation.

methodsWe enrolled consecutive patients who underwent a second AF ablation procedure for PAF in a UK tertiary center after an index ablation conducted between 2018 and 2019 and a repeat ablation up to 2021. A digital 12-lead ECG was recorded with a 1-50-Hz bandpass filter applied. P-wave duration (PWD), P-wave voltage (PWV), P-wave dispersion (PWDisp), and P-wave terminal force in V1 (PTFV1) were measured before and after the procedure. Changes were correlated with the 12-month clinical outcome. Procedural success was freedom from ECG-documented AF up to 12 months following ablation.

resultsStudy criteria were satisfied by 72 patients, of which 43 (60%) had successful repeat PVI at 12 months. The mean age is 65, and 47 (65%) were males. The demographics were comparable between both study arms. PWD decreased after successful repeat ablations (136.7 to 124.6 ms, p = 0.01) and failed repeat ablations (135.4 to 125.3 ms, p = 0.009) without a significant change between both arms. PMV and PWDisp did not change significantly after both study arms. PTFV1 significantly decreased after successful repeat ablations (-3.1 to -4.4 mm.s, p = 0.005) without a significant change after failed ablations (-2.9 to -2.7 mm.s, p = 0.42). Changes were statistically significant between both arms (p = 0.004).

conclusionPTFV1 reduction following the second AF ablation was correlated with successful repeat AF ablation at 12 months.

Indexed as

Atrial FibrillationCatheter AblationElectrocardiographyAgedFemaleHumansMaleMiddle AgedPredictive Value of TestsPulmonary VeinsReoperationTreatment Outcomeatrial fibrillationPTFV1P‐wavesrepeat ablation

Identifiers

PMID39717950
PMCPMC11708455

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.