Evidence map›Paper›PMID 39717566›Full record

ArticlePractical laboratory medicine2024

Assay precision, 99th percentile reference value and proportion of detected healthy european adults for VIDAS® high-sensitive troponin I.

Nathalie Auberger, Isabelle Coin, Laure Marillet, Frédérique Raymond, Sandrine Michel-Busseret, Pierre-Géraud Claret, Camille Pease

Abstract read
In one paragraph

Article in Practical laboratory medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nathalie AubergerbioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.
Isabelle CoinbioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.
Laure MarilletbioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.
Frédérique RaymondbioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.
Sandrine Michel-BusseretbioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.
Pierre-Géraud ClaretbioMérieux, Department of Medical Affairs, Marcy-l'Étoile, France.
Camille PeasebioMérieux, Department of Research and Development for Immunoassays, Marcy-l'Étoile, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction/objectives: Following the IFCC (The International Federation of Clinical Chemistry and Laboratory Medicine) guidelines concerning high-sensitivity cardiac troponin assays, we performed an assessment of the VIDAS® High-Sensitive Troponin I (TNHS) assay. The test was evaluated on its capacity to detect at least 50 % of healthy individuals and checked that the coefficient of variation was less than 10 % at the 99th percentile. Methods: High-sensitivity performance was assessed by examining the limits of detection, the determination of the 99th percentile value, the evaluated imprecision at said value and the detectable results above limit of detection (LoD) in a cohort of healthy European individuals. The capacity of detection on a healthy population of VIDAS® TNHS was validated on a total of 808 plasma samples. Results: One thousand six hundred and nineteen values (888 values for male samples and 731 values for female samples) were included in the analysis. The total imprecision of VIDAS® High-Sensitive Troponin I assay at the 99th percentile was 5.2 %, and 57.4 % of healthy individuals had troponin I values exceeding the LoD. Since the test detected more than 50 % of healthy individuals and had a coefficient of variation less than 10 % at the 99th percentile, it met the criteria of high-sensitivity cardiac troponin assays. Conclusion: VIDAS® High-Sensitive Troponin I assay is a high-sensitivity cardiac troponin assays meeting the definition provided by IFCC guidelines.

Indexed as

99th percentileCardiac troponin IDetection limitsHealthy cohortHigh-sensitivity

Identifiers

PMID39717566
PMCPMC11665417

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390