ArticleAdvances in radiation oncology2025
Comprehensive Image Quality Evaluation and Motion Phantom Studies of an Ultra-Fast (6-Second) Cone-Beam Computed Tomography Imaging System on a Ring Gantry Linear Accelerator.
Article in Advances in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed.
- HyperSight CBCT dose calculation accuracy for adaptive head and neck radiotherapy: Results from a prospective clinical trial.Medical physics · 2026Trial
- HyperSight CBCT image quality and metal artifact reduction for adaptive head and neck radiotherapy: Results from a prospective clinical trial.Journal of applied clinical medical physics · 2025Trial
- Evaluating Image Quality of Cone Beam Computed Tomography Using HyperSight® on the Varian TrueBeam.Annals of biomedical engineering · 2026Article
- Development of CBCT-Guided Online Adaptive Radiotherapy.Cancers · 2026Review
- Effects of air on the dosimetric robustness of treatment plans for prostate cancer in the presence of intrafractional, anatomical changes during online adaptive radiotherapy.Journal of applied clinical medical physics · 2026Article
- Evaluation of tumor localization accuracy on fast ring-gantry cone-beam computed tomography using patient-specific breathing curves and a dynamic anthropomorphic thorax phantom.Physics and imaging in radiation oncology · 2026Article
- Simulated online adaptive radiotherapy on C-arm linacs: Integrating high resolution cone-beam CT into abdominal stereotactic body radiation therapy.Journal of applied clinical medical physics · 2026Article
- Multi-institutional validation of hypersight CBCT-based dose calculation on O-ring linacs.Journal of applied clinical medical physics · 2026Article
- A clinical evaluation of HyperSight CBCT enhanced offline adaptive breast radiotherapy.Frontiers in oncology · 2026Article
- Impact of tumor motion on target delineation and dose calculation accuracy using rapid-acquisition HyperSight CBCT in online adaptive radiotherapy.Journal of applied clinical medical physics · 2026Article
- Correlation between exposure (mAs) and image quality for a rapid cone-beam CT on a ring gantry linear accelerator.Journal of applied clinical medical physics · 2025Article
- A hybrid population-based and patient-specific framework for 2D-3D deformable registration-driven limited-angle cone-beam CT estimation.Medical physics · 2025Article
- Real-time volumetric CBCT reconstruction using surface and X-ray imaging for image-guided radiotherapy.Medical image analysis · 2025Article
- Optimizing Treatment Precision: Role of Adaptive Radiotherapy in Modern Anal Cancer Management.Cancers · 2025Review
- Localization accuracy of 6-second CBCT for lung IGRT with various breathing patterns.Journal of applied clinical medical physics · 2025Article
- Are treatment plans optimized on the basis of acuros XB dose calculation robust against anatomic changes during online adaptive radiotherapy for lung cancer regarding dose homogeneity?Radiation oncology (London, England) · 2025Article
- Multi-institutional Comparison of Novel O-ring Linac Cone Beam Computed Tomography with Fan Beam Computed Tomography.Journal of medical physicsArticle
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight. Methods and Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT. Second, a visual comparison of image quality among simulation-CTs, HyperSight CBCT, and TrueBeam CBCT was performed for a patient with head and neck cancer and patients with metal dental fillings and prostheses. Third, the Hounsfield unit (HU) versus electron density curve of HyperSight CBCT was compared with GE and Siemens simulation CTs. Fourth, Siemens simulation-CT and HyperSight CBCT scans were acquired on the Catphan set-up at different locations inside the bore (±10 cm in all 3 principal directions from the center), and the HU variations for different materials were evaluated. Fifth, a 4-dimensional lung tumor phantom study was performed to assess moving tumor alignment during image registration. Results: Significant improvement of image contrast, HU constancy, and noise level on HyperSight CBCT was observed compared with TrueBeam CBCT. Significant image quality improvement was observed on HyperSight CBCT for patients with dental fillings and prostheses compared with simulation-CT without metal artifact reduction. The linear fit trendline of HU versus electron density curves for GE simulation-CT, Siemens simulation-CT, and HyperSight CBCT showed a 0.6% difference for HU values below 2000. The maximum HU difference for HyperSight CBCT when Catphan was positioned within ±10 cm in all 3 principal directions was ≤ 98 on bone 50%, ≤ 29 other than bone, and was ≤ 31 on bone 50%, and ≤ 17 other than bone for Siemens simulation-CT. Both tumor shape and tumor alignment discrepancies on CBCT scans were observed in a 4-dimensional phantom study. Conclusions: This evaluation shows significant image improvement of HyperSight CBCT over conventional CBCT on image contrast, HU constancy, and noise level with scatter correction and metal artifact reduction reconstruction methods. HyperSight CBCT has similar image quality to simulation-CTs and shows the potential application for treatment planning. The rapid acquisition of HyperSight CBCT showed both tumor shape and tumor alignment discrepancies of moving targets. Careful considerations of patient respiratory motion monitoring and target matching are highly recommended.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.