ArticleMedical physics2025
Detection of an internal density change in an anthropomorphic head phantom via tracking of charged nuclear fragments in carbon-ion radiotherapy.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Out-of-beam artifact suppression in charged nuclear fragment based carbon-ion radiotherapy monitoring.Medical physics · 2026Article
- The Role of Molecular Imaging in Ion Beam Therapy.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2026Review
- LET measurements in proton and helium-ion beams of therapeutic energies using a silicon pixel detector towards a tool for quality assurance.Medical physics · 2025Article
- Detection of an internal density change in an anthropomorphic head phantom via tracking of charged nuclear fragments in carbon-ion radiotherapy.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
backgroundCarbon-ion radiotherapy provides steep dose gradients that allow the simultaneous application of high tumor doses as well as the sparing of healthy tissue and radio-sensitive organs. However, even small anatomical changes may have a severe impact on the dose distribution because of the finite range of ion beams. PURPOSE: An in-vivo monitoring method based on secondary-ion emission could potentially provide feedback about the patient anatomy and thus the treatment quality. This work aims to prove that a clinically relevant anatomical change in an anthropomorphic head phantom may be detected via charged-fragment tracking during a treatment fraction.
methodsA clinically representative carbon-ion treatment plan was created for a skull-base tumor in an anthropomorphic head phantom. In order to imitate an inter-fractional anatomical change - for example, through tissue swelling or mucous accumulation - a piece of silicone was inserted into the nasopharynx. Fragment distributions with and without the silicone insert were subsequently acquired with a mini-tracker made of four hybrid silicon pixel detectors. Experimental irradiations were carried out at the Heidelberg Ion Beam Therapy Centre (HIT, Germany). FLUKA Monte Carlo simulations were performed to support the interpretation of the experimental results.
resultsIt was found that the silicone causes a significant change in the fragment emission that was clearly distinguishable from statistical fluctuations and setup uncertainties. Two regions of fragment loss were observed upstream and downstream of the silicone with similar amplitude in both the measurement and the simulation. Monte Carlo simulations showed that the observed signature is a consequence of a complex interplay of fragment production, scattering, and absorption.
conclusionsCarbon-ion therapy monitoring with charged nuclear fragments was shown to be capable of detecting clinically relevant density changes in an anthropomorphic head phantom under realistic clinic-like conditions. The complexity of the observed signal requires the development of advanced analysis techniques and underscores the importance of Monte Carlo simulations. The findings have strong implications for the ongoing InViMo clinical trial at HIT, which investigates the feasibility of secondary-ion monitoring for skull-base cancer patients.
Indexed as