Evidence map›Paper›PMID 39714195›Full record

ArticleThe Journal of the Acoustical Society of America2024

Pressure estimation of ultra-high frequency ultrasound using gas vesicles.

Eric M Strohm, Di Wu, Dina Malounda, Rohit Nayak, Mikhail G Shapiro, Michael C Kolios

Abstract read
In one paragraph

Article in The Journal of the Acoustical Society of America, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Acoustic percolation switches enable targeted drug delivery controlled by diagnostic ultrasound.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eric M StrohmDepartment of Physics, Toronto Metropolitan University (formerly Ryerson University), Toronto, Ontario M5B 2K3, Canada.ORCID 0000-0003-0130-9360
Di WuDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA.
Dina MaloundaDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA.ORCID 0000-0001-7086-9877
Rohit NayakDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA.
Mikhail G ShapiroDivision of Chemistry and Chemical Engineering, California Institute of Technology, Pasadena, California 91125, USA.ORCID 0000-0002-0291-4215
Michael C KoliosDepartment of Physics, Toronto Metropolitan University (formerly Ryerson University), Toronto, Ontario M5B 2K3, Canada.

Funding

Biogenic Gas Nanostructures As Molecular Imaging Reporters For UltrasoundR01EB018975 · NIBIB · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI Mikhail Shapiro · 2014 to 2026
$5.9M
NIBIB NIH HHS R01 EB018975
6 · The paper itself

Abstract

Acoustic microscopy uses ultra-high frequency (UHF) ultrasound transducers over 80 MHz to perform high-resolution imaging. The pressure output of these transducers is unknown, as commercial calibrated hydrophones can measure pressure for transducers with frequencies only up to 80 MHz. This study used gas vesicle nanostructures (GVs) that collapse at 571 kPa to estimate the pressure of UHF transducers at 40, 80, 200, and 375 MHz. Agarose phantoms containing GVs were made, and a baseline ultrasound image was performed at low pressure to prevent GV collapse. Sections within the phantom were scanned at varying voltage to determine the GV collapse threshold. The pressure at full driving voltage was then calculated, assuming a linear relation between transducer voltage and pressure. The pressure calculated for the 40 MHz transducer was 2.2 ± 0.1 MPa at 21 °C. Using a hydrophone, the measured pressure was 2.1 ± 0.3 MPa, a difference of <2%, validating the method at this frequency. The pressure calculated for the other transducers was 2.0 ± 0.1 MPa (80 MHz), 1.2 ± 0.1 (200 MHz), and 1.05 ± 0.17 (375 MHz at 37 °C). This study addresses the challenge of estimating pressure output from UHF ultrasound transducers, demonstrating that the pressure output in the 40-400 MHz frequency range can be quantified.

Identifiers

PMID39714195
PMCPMC12661650

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked