Evidence map›Paper›PMID 39713914›Full record

ArticleActa orthopaedica2024

A new tibial insert design with ball-in-socket medial conformity and posterior cruciate ligament retention has low tibial baseplate migration after unrestricted kinematically aligned total knee arthroplasty: a cohort study using radiostereometric analysis.

Abigail E Niesen, Pranav A Tirumalai, Stephen M Howell, Maury L Hull

Abstract read
In one paragraph

Article in Acta orthopaedica, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Abigail E Niesenepartment of Biomedical Engineering, University of California, Davis, CA, USA.
Pranav A TirumalaiDepartment of Biomedical Engineering, University of California, Davis, CA, USA.
Stephen M HowellDepartment of Biomedical Engineering, University of California, Davis, CA, USA.
Maury L HullDepartment of Biomedical Engineering, University of California, Davis, CA; Department of Mechanical Engineering, University of California, Davis, CA; Department of Orthopaedic Surgery, University of California Davis Medical Center, Sacramento, CA, USA. mlhull@ucdavis.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeIn total knee arthroplasty (TKA), an insert with ball-in-socket (BS) medial conformity (MC) and posterior cruciate ligament (PCL) retention restores kinematics closer to native than an insert with intermediate (I) MC. However, high medial conformity might compromise baseplate stability as indicated by maximum total point motion (MTPM). Using the BS MC insert with PCL retention, we aimed to determine whether (i) the baseplate is stable as indicated by mean MTPM < 0.5 mm, (ii) baseplate stability is not strongly correlated to varus baseplate alignment, and (iii) baseplate stability, clinical outcome scores, and flexion are comparable with that of an I MC insert cohort which has demonstrated high stability, clinical outcome scores, and flexion.

methodsUnrestricted kinematic alignment (unKA) TKA was performed on a cohort of 35 patients using a cemented baseplate. Biplanar radiographs acquired at timepoints up to 12 months were processed with model-based radiostereometric analysis (RSA) software to determine MTPM.

resultsAt 1 year, mean MTPM of 0.35 mm was significantly below 0.5 mm (P < 0.001). MTPM was not strongly correlated to varus baseplate alignment up to 9° (r = 0.12, 95% confidence interval -0.22 to 0.44). Equivalence analyses revealed that MTPM, Forgotten Joint Score, Oxford Knee Score, and maximum flexion for the sBS MC insert were comparable with the I MC insert.

conclusionUsing the new BS MC insert with PCL retention, the tibial baseplate was stable at the group level at 1 year. Baseplate stability was not strongly related to varus baseplate and limb alignment. Comparable patient-reported outcome scores and maximum flexion/extension at 1 year were shown between the 2 insert designs.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisPosterior Cruciate LigamentProsthesis DesignRadiostereometric AnalysisAgedAged, 80 and overBiomechanical PhenomenaCohort StudiesFemaleHumansMaleMiddle AgedOsteoarthritis, KneeProsthesis FailureRange of Motion, Articular

Identifiers

PMID39713914
PMCPMC11664436

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.