Evidence map›Paper›PMID 39713229›Full record

ArticleInternational journal of cardiology. Congenital heart disease2024

Percutaneous pulmonary valve implantation guided by three-dimensional rotational angiography.

Gregor J Krings, Bart W Driesen, Evangeline G Warmerdam, Mirella C Molenschot, Gert-Jan T Sieswerda, Pieter A Doevendans, Arie P J van Dijk, M Voskuil

Abstract read
In one paragraph

Article in International journal of cardiology. Congenital heart disease, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Right ventricular pressure-volume loop analysis in congenital heart disease.International journal of cardiology. Congenital heart disease · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Gregor J KringsDepartment of Pediatric Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Bart W DriesenDepartment of Pediatric Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Evangeline G WarmerdamDepartment of Pediatric Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Mirella C MolenschotDepartment of Pediatric Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Gert-Jan T SieswerdaDepartment of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Pieter A DoevendansDepartment of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
Arie P J van DijkDepartment of Cardiology, Radboud University Medical Center, Nijmegen, the Netherlands.
M VoskuilDepartment of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: To describe the workflow and value of three-dimensional rotational angiography (3DRA) in percutaneous pulmonary valve implantation (PPVI). Background: 3DRA offers visualization of the entire topography in the chest and may enhance safety and reduce the risk for complications in PPVI through improved pre-procedural planning and per-procedural guidance. Methods: All PPVI procedures with the use of 3DRA performed between August 2011 and December 2022 were reviewed. Success rate, complications and radiation dose were assessed. Radiation dose of the latest 3DRA protocol was compared to historical 3DRA data. Results: PPVI was successful in 95 of 102 procedures. Seven procedures were aborted due to coronary compression after balloon testing (n = 3), main pulmonary artery (MPA) oversize (n = 3) and not passing of a Melody valve through a calcified Melody valve in situ (n = 1). PPVI was attempted in 61 homografts, 19 native right ventricular outflow tracts (including transannular patch), 4 previously implanted Melody valves, 2 in previously implanted Sapien valves and 16 in other bioprosthetic valves. A Melody valve was implanted in 43, a Sapien valve in 49 and a Pulsta valve in 1 patient. In 2 patients a Melody as well as a Sapien valve were subsequently implanted. Mean total dose area product (DAP) was 11813 mGycm Conclusions: The use of rotational angiography for the guidance of PPVI results in a high success rate, low number of complications with the use of a low amount of radiation.

Indexed as

Congenital heart diseaseCoronary compressionPercutaneous pulmonary valve implantationPulmonary artery stentingThree-dimensional rotational angiography

Identifiers

PMID39713229
PMCPMC11658213

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.