Evidence map›Paper›PMID 39712370›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2024

Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Extended Depth-of-Focus Intraocular Lens.

Javier Ferrando Gil, Adela Churruca Irazola, Iraia Reparaz, Gorka Lauzirika, Itziar Martínez-Soroa, Javier Mendicute

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Observational
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Javier Ferrando GilDepartment of Ophthalmology, Donostia University Hospital, Donostia-San Sebastián, Spain.
Adela Churruca IrazolaDepartment of Ophthalmology, Donostia University Hospital, Donostia-San Sebastián, Spain.
Iraia ReparazDepartment of Ophthalmology, Donostia University Hospital, Donostia-San Sebastián, Spain.
Gorka LauzirikaMiranza Begitek, Donostia-San Sebastián, Spain.ORCID 0000-0002-4123-1521
Itziar Martínez-SoroaDepartment of Ophthalmology, Donostia University Hospital, Donostia-San Sebastián, Spain.
Javier MendicuteDepartment of Ophthalmology, Donostia University Hospital, Donostia-San Sebastián, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To describe the visual, refractive, functional, and patient satisfaction outcomes of the Bi-Flex POB-MA 877PEY (Elon Patients and Methods: This was a prospective longitudinal descriptive study. Patients who underwent cataract surgery with the implantation of Bi-Flex POB-MA 877PEY IOL were included. Monocular refractive outcomes and visual acuity at distance, intermediate, and near were evaluated 1- and 3-month post-op. Binocular contrast sensitivity (CSV-1000, VectorVision, USA), binocular defocus curve, and patient satisfaction with the Visual Functioning Questionnaire (VFQ) were assessed at 3-month post-op. Results: 20 Bi-Flex POB-MA 877PEY IOL were implanted bilaterally in 10 patients. The mean age of the patients was 68.60±4.45 years. At 1-month post-op the monocular Corrected Distance Visual Acuity (CDVA), intermediate (CIVA) and near (CNVA) was 0.02±0.03, 0.29±0.08, and 0.40±0.05 LogMAR respectively. At 3-month post-op the CDVA decrease to 0.05±0.06 LogMAR (p=0.042), and CIVA and CNVA remained stable at 3-month post-op (p>0.05). No statistical differences were found in post-op spherical equivalent at 1 and 3 month (-0.03±0.19 D and -0.03±0.13 D; p=1.000). 100% of eyes were within ±0.5 D at 1 month and 3-month post-op. Binocular defocus curve shows a peak of maximum visual acuity (VA) at 0 D (0.00±0.04 LogMAR), and a constant and progressive decrease at -1.50 D, and -2.50 D (0.15±0.08 LogMAR and 0.33±0.10 LogMAR, respectively). Contrast sensitivity decreased at high spatial frequencies. In patient satisfaction at 3 months post-op, VFQ reveals that 90% of patients revealed no or minor difficulty with glare/flare and 100% of patients have no or minor difficulty with halos. In overall satisfaction, 80% of patients rate their vision between 8 and 9 from a scale from 0 to 10. Conclusion: The Bi-Flex POB-MA 877PEY EDoF IOL provides good visual outcomes for distance, and adequate intermediate vision, with low visual disturbances.

Indexed as

cataract surgeryEDoF IOLphacoemulsification

Identifiers

PMID39712370
PMCPMC11662917

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.