Evidence map›Paper›PMID 39712353›Full record

ArticleThe journal of Tehran Heart Center2024

In-Hospital and Midterm Outcomes of Lead Extraction: A Single-Center Clinical Study.

Fahimeh Valizadeh-Shiran, Negin Sadat Hosseini Mohammadi, Kiarash Tavakoli, Arash Jalali, Seyed Hossein Ahmadi Tafti, Ahmad Yaminisharif

Abstract read
In one paragraph

Article in The journal of Tehran Heart Center, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fahimeh Valizadeh-ShiranDepartment of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Negin Sadat Hosseini MohammadiDepartment of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Kiarash TavakoliDepartment of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Arash JalaliCardiac Primary Prevention Research Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Seyed Hossein Ahmadi TaftiCardiac Primary Prevention Research Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.
Ahmad YaminisharifDepartment of Cardiac Electrophysiology, Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The rate of lead extraction has steadily increased alongside the extensive use of cardiovascular implantable electronic devices. Data on the complications and safety of this challenging procedure are limited. We investigated inhospital and midterm outcomes following lead extraction. Methods: Data were retrieved from 51 patients who underwent pacemaker/defibrillator lead extraction procedures at Tehran Heart Center between 2016 and 2021. The procedural success rate, patients' demographic characteristics, and inhospital and midterm procedure-related complications were investigated. Results: Fifty-one patients were enrolled, including 44 men (86.3%). A total of 109 leads were extracted, with a 90.2% complete procedural success rate. In-hospital death occurred in 4 patients (7.8%): 1 patient (1.9%) died from pneumonia, 1 (1.9%) from septic shock, and 2 (3.9%) from septic shock besides heparin-induced thrombocytopenia. Adverse events in 3 patients (5.8%) were directly related to the procedure: 1 patient (1.9%) suffered lung laceration and hemorrhage, 1 (1.9%) sustained subclavian injury, and 1 (1.9%) developed tamponade. Neither reinfection nor rehospitalization was observed during follow-up. Conclusion: Lead extraction can be considered a highly successful procedure with a low rate of death-related events and complications.

Indexed as

Cardiac resynchronization therapyCardiac resynchronization therapy devicesImplantable cardioverter-defibrillatorsLead

Identifiers

PMID39712353
PMCPMC11659709

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.