ArticleInternational journal of cardiology. Congenital heart disease2022
A Novel Technique to Reduce Branch Pulmonary Artery Diameter During Transcatheter Pulmonary Valve Replacement Utilizing Side-by-Side Transcatheter Valves in a Superior-Inferior Orientation.
Article in International journal of cardiology. Congenital heart disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Transcatheter pulmonary valve replacement (TPVR) is increasingly used to treat complications related to dysfunctional right ventricular outflow tracts (RVOT). Candidacy is limited by RVOT diameter and coronary artery anatomy. We present the case of a branch pulmonary artery (BPA) that was too large to accommodate a single TPVR and underwent placement of 2 TPVR. Clinical case: The patient is a 54-year-old with a history of pulmonary valve stenosis who underwent a Brock procedure at 8 years-old. He presented due to NYHA class 3 heart failure symptoms. He underwent an extensive work up and he was recommended to undergo TPVR because he was a poor surgical candidate due to comorbidities.Coronary compression testing showed distortion of the right coronary cusp preventing traditional TPVR. He had a dilated, dynamic right pulmonary artery (RPA). Based on balloon sizing he underwent deployment of 2 stents simultaneously in a superior-inferior manner in the RPA. A 22 mm Melody valve was deployed in both stents. He returned to the cath lab 5 weeks later. At that time an angiogram showed good function of the valves with trivial insufficiency. A 26 mm Edwards Sapien 3 valve was then deployed into the left pulmonary artery. Discussion: This case demonstrates that a "double valve" strategy is feasible when the native vessel is too large for current TPVR. Satisfactory valve function is present at early follow up.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.