ArticleClinical oral implants research2025

Evaluation of Exomass-Related Artefacts Caused by Dental Implants of Different Materials in Cone-Beam Computed Tomography Scans: An Ex Vivo Study.

Matheus L Oliveira, Dorothea Dagassan-Berndt, Matheus Sampaio-Oliveira, Michelle Simonek, Sebastian Kühl, Michael M Bornstein

Abstract read
In one paragraph

Article in Clinical oral implants research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Matheus L OliveiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil.ORCID 0000-0002-8054-8759
Dorothea Dagassan-BerndtDepartment of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland.ORCID 0000-0003-1109-8763
Matheus Sampaio-OliveiraDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil.ORCID 0000-0002-0414-6395
Michelle SimonekDepartment of Oral Surgery, University, Center for Dental Medicine, University of Basel, Basel, Switzerland.ORCID 0009-0005-4740-9350
Sebastian KühlDepartment of Oral Surgery, University, Center for Dental Medicine, University of Basel, Basel, Switzerland.ORCID 0000-0002-3174-135X
Michael M BornsteinDepartment of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland.ORCID 0000-0002-7773-8957

Funding

Fundação de Amparo à Pesquisa do Estado de São Paulo #2022/12994-0Swiss Association of Dentomaxillofacial Radiology (SGDMFR/SADMFR) #23/01
6 · The paper itself

Abstract

objectivesTo evaluate the influence of different dental implant materials within the exomass on the image quality in cone-beam computed tomography (CBCT). MATERIAL AND

methodsFive pig jaws were scanned using four CBCT devices, first without any dental implants, followed by scans with three dental implants of the same material-pure titanium, titanium-zirconium alloy, and zirconium dioxide. Two fields of view (FOVs) were used for each device to position the implants in the exomass of a small FOV and within a large FOV. Voxel values were obtained from tubes containing a radiopaque solution to calculate mean voxel value (MVV), voxel value inhomogeneity (VVI), and image noise (IN), which were compared across implant materials and FOVs using repeated measures analysis of variance (α = 0.05). Three observers independently scored image quality using a 5-point scale.

resultsIn general, MVV remained unaffected, except for a significant increase in the X800 device when titanium or titanium-zirconium alloy implants were in the exomass of a small FOV (p ≤ 0.05). A trend of increased VVI was observed when implants were in the exomass of a small FOV, with a greater effect for zirconium dioxide, followed by titanium-zirconium alloy and titanium. IN was higher when implants were in the exomass, especially for zirconium dioxide implants (p ≤ 0.05). Image quality perception was consistent overall, though zirconium dioxide implants in both FOVs resulted in diminished quality.

conclusionsThe presence of implants in the exomass can negatively affect CBCT image quality, with zirconium dioxide having the greatest impact.

Indexed as

ArtifactsCone-Beam Computed TomographyDental ImplantsDental MaterialsAnimalsSwineTitaniumZirconiumDental ImplantsDental MaterialsTitaniumZirconiumzirconium oxidecone‐beam computed tomographydental implantstitaniumzirconium

Identifiers

PMID39707609
PMCPMC11996732

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.