ArticleJournal of applied clinical medical physics2025
Development and application of a novel scintillation gel-based 3D dosimetry system for radiotherapy.
Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Development and application of a novel scintillation gel-based 3D dosimetry system for radiotherapy.Journal of applied clinical medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeThis study introduced a novel 3D dosimetry system for radiotherapy in order to address the limitations of traditional quality assurance methods in precision radiotherapy techniques.
methodsThe research required the use of scintillation material, optical measurements, and a dose reconstruction algorithm. The scintillation material, which mimics human soft tissue characteristics, served as a both physical phantom and a radiation detector. The dose distribution inside the scintillator can be converted to light distributions, which were measured by optical cameras from different angles and manifested as pixel values. The proposed dose reconstruction algorithm, LASSO-TV, effectively reconstructed the dose distribution from pixel values, overcoming challenges such as limited projection directions and large-scale matrices.
resultsVarious clinical plans were tested and validated, including a modified segment from the SBRT plan and IMRT clinical plan. The dosimetry system can execute full 3D dose determinations as a function of time with a spatial resolution of 1-2 mm, enabling high-resolution measurements for dynamic dose distribution. Comparative analysis with mainstream device MapCHECK2 confirmed the accuracy of the system, with a relative measurement error of within 5%.
conclusionsTesting and validation results demonstrated the dosimetry system's promising potential for dynamic treatment quality assurance.