Evidence map›Paper›PMID 39703690›Full record

ArticleJournal of Taibah University Medical Sciences2024

Fracture resistance of monolithic gradient zirconia crowns with different finish line designs and cement spaces.

Mohammed H AbdElaziz, Mohamed F Aldamaty, Elsayed Ali Omar, Adel A Elbadawy, Sary Borzangy, Ahmed Y Alqutaibi, Muhammad S Zafar

Abstract read
In one paragraph

Article in Journal of Taibah University Medical Sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Mohammed H AbdElazizSubstitutive Dental Sciences Department, College of Dentistry, Taibah University, Almadinah Almunawwarah 41311, KSA.
Mohamed F AldamatyDepartment of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11651, Egypt.
Elsayed Ali OmarDepartment of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11651, Egypt.
Adel A ElbadawyDepartment of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo 11651, Egypt.
Sary BorzangySubstitutive Dental Sciences Department, College of Dentistry, Taibah University, Almadinah Almunawwarah 41311, KSA.
Ahmed Y AlqutaibiSubstitutive Dental Sciences Department, College of Dentistry, Taibah University, Almadinah Almunawwarah 41311, KSA.
Muhammad S ZafarDepartment of Clinical Sciences, College of Dentistry, Ajman University, Ajman, United Arab Emirates.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study was aimed at assessing the effects of various finish line designs and cement gap thicknesses on the fracture resistance of gradient zirconia crowns. Methods: Sixty crowns were fabricated on stainless-steel dies with yttria multi-layered (YML) zirconia and categorized into three primary groups according to finish line type (knife-edge, chamfer, and rounded shoulder). Each group was further classified into two subgroups (n = 10) according to cement space thickness (50 or 80 μm). Optical impressions of the dies were acquired with an indirect laboratory scanner, and cement spaces (50 or 80 μm) were established for each finish line type in Exocad software. Subsequently, the zirconia crowns were milled, sintered, cemented onto their respective dies, thermomechanically aged, and subjected to loading until fracture. The data were statistically analyzed with one-way ANOVA and post hoc tests for pairwise comparisons. Additionally, two-way ANOVA was used to investigate interactions between two study variables. Results: No significant differences between chamfer and knife-edge patterns were observed, whereas the rounded shoulder pattern exhibited significantly higher failure load values. Similarly, no significant difference was observed between 50 μm and 80 μm cement space. Conclusions: Knife-edge margins with YML gradient zirconia crowns provide a reliable alternative to shoulder margins, particularly in minimally invasive preparations. A cement space of 80 μm rather than 50 μm is preferred for various finish line designs.

Indexed as

Cement space thicknessChamfer finish lineFracture resistanceGradient zirconiaKnife-edge finish lineShoulder finish line

Identifiers

PMID39703690
PMCPMC11655682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.