Evidence map›Paper›PMID 39703197›Full record

ArticleJOR spine2024

Scoliosis instrumentation alters primary and coupled motions of the spine: An in vitro study using entire thoracolumbar spine and rib cage specimens.

Christian Liebsch, Peter Obid, Morten Vogt, Benedikt Schlager, Hans-Joachim Wilke

Abstract read
In one paragraph

Article in JOR spine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Coupled motions of the spine under standardizedFrontiers in bioengineering and biotechnology · 2025
    Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Christian LiebschInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University Medical Centre Ulm Germany.ORCID https://orcid.org/0000-0003-1543-4728
Peter ObidDepartment of Orthopaedics and Trauma Surgery Freiburg University Medical Centre Freiburg Germany.ORCID https://orcid.org/0000-0003-4923-1064
Morten VogtInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University Medical Centre Ulm Germany.ORCID https://orcid.org/0009-0009-6030-8545
Benedikt SchlagerInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University Medical Centre Ulm Germany.ORCID https://orcid.org/0000-0003-2371-851X
Hans-Joachim WilkeInstitute of Orthopaedic Research and Biomechanics, Trauma Research Centre Ulm, Ulm University Medical Centre Ulm Germany.ORCID https://orcid.org/0000-0001-6007-8844

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Effects of rigid posterior instrumentation on the three-dimensional post-operative spinal flexibility are widely unknown. Purpose of this in vitro study was to quantify these effects for characteristic adolescent idiopathic scoliosis instrumentations. Methods: Six fresh frozen human thoracic and lumbar spine specimens (C7-S) with entire rib cage from young adult donors (26-45 years) without clinically relevant deformity were loaded quasi-statically with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation. Primary and coupled motions of all segments were measured using optical motion tracking. Specimens were tested without instrumentation and with posterior rod instrumentations ranging from T2 to L1 (for Lenke Type 2) and from T8 to L3 (for Lenke Type 5) based on survey results among spinal deformity surgeons. Statistical differences were evaluated using the pairwise Friedman test. Results: Primary ranges of motion were significantly ( Conclusions: Instrumentation reduces the primary flexibility and diminishes the natural coupling behavior between lateral bending and axial rotation, primarily in the upper thoracic spine, potentially causing correction loss and junctional deformity in the long-term.

Indexed as

adolescent idiopathic scoliosisbiomechanicscoupled motionsin vitro studylumbar spineposterior instrumentationrange of motionrib cagethoracic spine