Evidence map›Paper›PMID 39698684›Full record

ArticleQuantitative imaging in medicine and surgery2024

SPW-TransUNet: three-dimensional computed tomography-cone beam computed tomography image registration with spatial perpendicular window Transformer.

Rui Hu, Shimeng Yang, Jingjing Zhang, Xiaokun Hu, Teng Li

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rui HuKey Laboratory of Intelligent Computing and Signal Processing, Ministry of Education/School of Artificial Intelligence, Anhui University, Hefei, China.
Shimeng YangKey Laboratory of Intelligent Computing and Signal Processing, Ministry of Education/School of Artificial Intelligence, Anhui University, Hefei, China.
Jingjing ZhangKey Laboratory of Intelligent Computing and Signal Processing, Ministry of Education/School of Artificial Intelligence, Anhui University, Hefei, China.
Xiaokun HuDepartment of the Interventional Medical Center, the Affiliated Hospital of Qingdao University, Qingdao, China.
Teng LiKey Laboratory of Intelligent Computing and Signal Processing, Ministry of Education/School of Artificial Intelligence, Anhui University, Hefei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Current medical image registration methods based on Transformer still encounter challenges, including significant local intensity differences and limited computational efficiency when dealing with three-dimensional (3D) computed tomography (CT) and cone beam CT (CBCT) images. These limitations hinder the precise alignment necessary for effective diagnosis and treatment planning. Therefore, the aim of this study is to develop a novel method that overcomes these challenges by enhancing feature interaction and computational efficiency in 3D medical image registration. Methods: This paper introduces a novel method that enhances feature interaction within Transformer by computing attention within resizable spatial perpendicular window (SPW). Additionally, it introduces a self-learning mapping control (SLMC) mechanism, which uses a mini convolutional neural network (CNN) to adaptively transform feature vectors into probability vectors. This approach is integrated into the UNet framework, resulting in the SPW-TransUNet. The effectiveness of the SPW-TransUNet is demonstrated through evaluations on two critical 3D medical imaging tasks: CT-CBCT registration and inter-CT registration. We utilized a range of evaluation metrics including Dice similarity coefficient (DICE), structural similarity index measure (SSIM), target registration error (TRE), and negative Jacobian percentage. The validation process involved comparative analysis against established baseline methods using statistical tests to ensure the robustness and reliability of our results. Results: The proposed method demonstrated outstanding performance in the registration of 124 pairs of CT-CBCT lung images from 20 patients, achieving the lowest TRE of 2.16 mm and a minimal negative Jacobian of 0.126. It also recorded the highest SSIM and Dice coefficient of 86.87% and 88.28%, respectively. For the liver CT task involving 150 patients, the method achieved peak SSIM and DICE scores of 76.92% and 85.77%, respectively. Furthermore, ablation studies confirmed the effectiveness of the designed structural components. Conclusions: The SPW-TransUNet offers significant improvements in feature interaction and computational efficiency for medical image registration, providing an effective reference solution for patient and target localization in image-guided radiation therapy.

Indexed as

computed tomography-cone beam computed tomography registration (CT-CBCT registration)Spatial perpendicular window (SPW)three-dimensional medical image (3D medical image)Transformer

Identifiers

PMID39698684
PMCPMC11651926

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.