Evidence map›Paper›PMID 39698638›Full record

ArticleQuantitative imaging in medicine and surgery2024

Multi-scale perceptual modulation network for low-dose computed tomography denoising.

Jiexing Huang, Anni Zhong, Yujian Liu

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jiexing Huang *Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Anni Zhong *Department of Information Technology, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.
Yujian LiuDepartment of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Low-dose computed tomography (LDCT) reduces radiation exposure, but the introduced noise and artifacts impair its diagnostic accuracy. Convolutional neural networks (CNNs) are widely used for LDCT denoising, but they suffer from a limited receptive field. The use of a larger kernel size can enlarge the receptive field and boost model performance; however, the computational cost of the model greatly increases. We aimed to develop a LDCT denoising CNN with a large receptive field and lower computational complexity. Methods: We developed a multi-scale perceptual modulation network (MSPMnet) incorporating a powerful multi-head decomposable convolution (MHDC). To address the high computational complexity of large kernel convolutions, we developed a novel MHDC module that can capture multi-scale features and efficiently expand the receptive field. The MHDC module couples maximum-pooling with three depth-wise convolutions of varying kernel sizes via a channel splitting mechanism, where, unlike conventional CNNs, the two large two-dimensional kernels are each decomposed into a set of cascaded orthogonal one-dimensional kernels to remain lightweight. Further, departing from prior methodologies that apply a uniform kernel size throughout the network, we introduced a receptive field-ramp mechanism that adeptly transitions from local to relatively long-range dependency modeling as the network depth increases, thereby achieving superior performance. Results: The proposed MSPMnet was evaluated on a Mayo Clinic data set with a conventional iterative algorithm, two CNN models, and two Transformer models used for comparison. Compared to the competing baseline methods, the MSPMnet exhibited better performance in both the visual and quantitative assessments. Visually, the MSPMnet preserved the structure, edges, and textures with excellent noise and artifact reduction, generating the denoised images closest to normal-dose computed tomography images. Quantitatively, the MSPMnet had the lowest root mean-square error (RMSE) (8.3094±1.9325) and the highest peak signal-to-noise ratio (PSNR) (33.8525±1.8213 dB), structural similarity index (SSIM) (0.9309±0.0272), and feature similarity index (FSIM) (0.9699±0.0113), demonstrating superior denoising performance. Conclusions: The proposed MSPMnet excelled at LDCT denoising, effectively removing noise and artifacts while preserving edges. Compared to the state-of-the-art CNNs and Transformers, the proposed MSPMnet exhibited superior denoising performance both quantitatively and qualitatively.

Indexed as

decomposable convolutiondenoisingLow-dose computed tomography (LDCT)modulationmulti-scale perceptual

Identifiers

PMID39698638
PMCPMC11652037

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.