Evidence map›Paper›PMID 39697528›Full record

ArticleACS applied nano materials2024

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications.

Dolendra Karki, Tulika Khanikar, Suraj V Mullurkara, Khurram Naeem, Jun Young Hong, Paul Ohodnicki

Abstract read
In one paragraph

Article in ACS applied nano materials, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Dolendra KarkiMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.ORCID https://orcid.org/0000-0002-2438-8674
Tulika KhanikarMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Suraj V MullurkaraMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Khurram NaeemMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Jun Young HongMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.
Paul OhodnickiMechanical Engineering & Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

Identifiers

PMID39697528
PMCPMC11650606

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.