ReviewPatient safety in surgery2024
A novel minimally invasive neurosurgical cranial fixation device for improved accuracy of intraventricular catheter placement: an experimental animal study.
Review in Patient safety in surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Robot-Assisted versus non-robotic frame-based deep brain stimulation: a systematic review and meta-analysis of targeting accuracy and clinical outcomes.Journal of robotic surgery · 2026Pooled it
- A Low-Cost Articulated Arm Navigation System for External Ventricular Drain Placement.IEEE transactions on medical robotics and bionics · 2025Article
- Preventing What Matters: A Fast and Reliable Technique to Secure External Ventricular Drains and Avoid Dislodgement.Cureus · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExternal ventricular drain (EVD) insertion is one of the most commonly performed neurosurgical procedures. Herein, we introduce a new concept of a cranial fixation device for insertion of EVDs, that reduces reliance on freehand placement and drilling techniques and provides a simple, minimally invasive approach that provides strong fixation to minimal thickness skulls.
methodsAn experimental device for catheter insertion and fixation was designed and tested in both ex-vivo and in-vivo conditions to assess accurate cannulation of the ventricle and to test the strength of fixation to the skull. The ex-vivo experiments were conducted at Ben-Gurion University of the Negev (BGU) in Be'er Sheva, Israel. These experiments included functionality bench testing and pullout force measurements for the ball mechanism and catheter fixation. For the in-vivo experiments the fixation device was initially tested at the Cincinnati Children's Hospital Medical Center (CCHMC) in Cincinnati, Ohio on one day of life 1 (DOL 1) male control lamb. Additional experiments were conducted on 3 hydrocephalic DOL 0 lambs (1 male 2 female) at the Jesús Usón Minimally Invasive Surgery Centre (JUMISC) in Caceres, Spain. The hydrocephalic animal model used for this study was created with in utero intracisternal injection of BioGlue in fetal lambs. The catheter insertion trajectory was determined using MR imaging to assess the device's impact on the placement accuracy. The fixation device was evaluated on reaching the ventricle and enabling extraction of CSF for all 7 fixations placed. For 5 of the fixation devices, post-mortem pullout force was measured. The general functionality of the device was also evaluated.
resultsIn the experiments, 7/7 (100%) catheter trajectories successfully reached the ventricle without any apparent complications related to the device or the procedure. The cranial fixation device base demonstrated significant strength in withstanding an average pull-out force of 4.18kgf (STD[Formula: see text]0.72, N = 5) without detachment from the subject's skull for all 5 devices included in this test. Additionally, the EVD catheter pull test was conducted with the addition of a safety loop which did not allow movement of the EVD to a force of 3.6kgf. At this force the catheter tore but did not release from its fixation point.
conclusionThe newly designed experimental device demonstrates initial proof of concept from ex vivo and in vivo testing. It appears suitable for accurate ventricular catheter placement and cranial fixation.