ArticleCardiovascular intervention and therapeutics2025
Comparison of invasive and non-invasive gradients before and after TAVI and their implications on clinical outcomes.
Article in Cardiovascular intervention and therapeutics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Long-term outcomes after balloon- or self-expandable transcatheter aortic valve replacement in small aortic annuli.Cardiovascular intervention and therapeutics · 2026Article
- Insights from the assessment of anatomical valve orifice area after transcatheter aortic valve implantation using transesophageal echocardiography.Cardiovascular intervention and therapeutics · 2026Article
- Discrepancy Between Invasive and Echocardiographic Transvalvular Gradients After TAVI Procedure: A Review of the Literature.Journal of clinical medicine · 2026Review
- Extracorporeal Membrane Oxygenation in Acute Cardiovascular Care.Circulation reports · 2025Review
- Antithrombotic Management in Patients With Atrial Fibrillation Following Percutaneous Coronary Intervention: An Updated Clinical Review.Journal of arrhythmia · 2025Review
- Comparison of Echocardiography and Invasive Transseptal Catheterization for Assessing Transvalvular Gradient in Patients with Surgical Aortic Valve Prostheses: Fact or Myth?Diagnostics (Basel, Switzerland) · 2025Article
- Prognostic Utility of Left Ventricular Ejection Fraction in Patients Undergoing Transcatheter Aortic Valve Implantation - A Systematic Review and Meta-Analysis.Circulation reports · 2025Article
- Sex-Based Differences in Hemodynamic Response to Anesthesia Type During TAVI and Early Transvalvular Gradient Changes.Journal of clinical medicine · 2025Article
- Letter: When gradients diverge: integrating invasive assessment into post-TAVI surveillance.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Transcatheter aortic valve implantation (TAVI) is recommended for treatment of high-risk aortic stenosis patients. While measuring mean transaortic valve gradient (MG) is crucial in evaluating procedural success, echocardiographic measurements often overestimate direct invasive measurements. This study aimed to examine the discordance between echocardiographic and invasive MGs in TAVI patients and assess their prognostic value on long-term outcomes. This prospective registry included consecutive TAVI patients at a tertiary university hospital. Transthoracic or transoesophageal echocardiography was performed pre-TAVI, at discharge, 1 month, 1, and 5 years with invasive MG measurements obtained peri-procedurally. The primary endpoints were 5-year all-cause mortality and major adverse cardiac events. Among 1353 patients from 2011 to 2023, non-invasive MGs exceeded invasive MGs pre- and post-implantation (43 [36, 52] mmHg vs. 40 [30, 50] mmHg, p < 0.001; 9 [6, 12] mmHg vs. 4 [2, 7] mmHg, p < 0.001) Pre-procedural MGs correlated better than post-procedural MGs (r = 0.70, p < 0.001 vs. r = 0.23, p < 0.001), particularly in self-expandable valves and smaller sinus of Valsalva diameter (SOVd) (r = 0.33, p < 0.001; r = 0.46, p < 0.001 vs R = 0.06, p = 0.701). Non-invasive MG remained stable from discharge (9 [6, 12] mmHg) to 5 years (9 [7, 12] mmHg). While structural valve deterioration and patient-prosthesis mismatch showed no impact, extreme invasive MGs (< 3 or > 6 mmHg) predicted worse outcomes (mortality hazard: 1.25 [1.06, 1.88] and 0.85 [0.8, 0.95], respectively), unlike non-invasive measurements. In conclusion, invasive as compared with non-invasive MGs correlated better before than after valve implantation, whereas invasive MGs were always lower than non-invasive MGs. Lower invasive MGs after TAVI appeared to be associated with favourable long-term outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.