Evidence map›Paper›PMID 39694838›Full record

ArticleZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery2024

[Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury].

Lei Zhang, Minghui Li, Mengyao Zhang, Jixiang Xiong, Junqiu Wang, Xin Zhou, Houyin Shi, Guoyou Wang

Abstract readEnglish Abstract
In one paragraph

Article in Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. [Early internal fixation combined with free anterolateral thigh perforator flap transplantation to treat open ankle fracture-dislocation].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lei ZhangDepartment of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Minghui LiSchool of Physical Education, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Mengyao ZhangSchool of Clinical Medicine, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Jixiang XiongSchool of Clinical Medicine, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Junqiu WangDepartment of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Xin ZhouDepartment of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Houyin ShiDepartment of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Guoyou WangDepartment of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test. Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint. The displacement of fibula was measured by biomechanical testing machine at neutral, dorsiflexion (10°), plantar flexion (15°), varus (10°), and valgus (15°) positions, with axial load of 0-700 N (pressure separation test). The displacement of fibula was also measured at neutral position by applying 0-5 N·m torque load during internal and external rotation (torsional separation test). Results: In the pressure separation test, group C exhibited the smallest displacement under different positions and load conditions. At neutral position, significant differences were observed ( Conclusion: The ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury was 20°-25°, which has a small displacement of fibula.

Indexed as

Ankle InjuriesAnkle JointBone ScrewsFibulaFracture Fixation, InternalTibiaAdultBiomechanical PhenomenaCadaverFemaleHumansMalePlastic Surgery ProceduresRange of Motion, ArticularWeight-Bearingbiomechanicsimplant anglescrew fixationTibiofibular syndesmosis injury

Identifiers

PMID39694838
PMCPMC11655369