Evidence map›Paper›PMID 39693006›Full record

Trial reportJournal of the Egyptian National Cancer Institute2024

Value of using ultrasonic shears in reducing seroma formation after axillary lymph node dissection in breast cancer patients.

Yousra Mohsen Elshoura, Ahmed Refaat, Basma Hussein Abdelaziz Hassan, Philobater Bahgat Adly Awad, Mohamed Wael Ahmed, Sherif Mokhtar, Emad Salah El Din Khalaf

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Journal of the Egyptian National Cancer Institute, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yousra Mohsen ElshouraGeneral Surgery Department, Faculty of Medicine, Cairo University, Cairo, Egypt.
Ahmed RefaatGeneral Surgery Department, Faculty of Medicine, Cairo University, Cairo, Egypt.
Basma Hussein Abdelaziz HassanGeneral Surgery Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt.
Philobater Bahgat Adly AwadGeneral Surgery Department, Faculty of Medicine, Ain Shams University, Cairo, Egypt. Philobater@med.asu.edu.eg.
Mohamed Wael AhmedGeneral Surgery Department, Faculty of Medicine, Cairo University, Cairo, Egypt.
Sherif MokhtarGeneral Surgery Department, Faculty of Medicine, Cairo University, Cairo, Egypt.
Emad Salah El Din KhalafGeneral Surgery Department, Faculty of Medicine, Cairo University, Cairo, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAxillary lymph node dissection (ALND) is an essential step in the management of breast cancer. ALND is conventionally performed using radio frequency electrosurgery. The post-operative complications of utilizing such energy (such as prolonged drainage time, seroma, or infection) lead to prolonged recovery. Hence, it may delay the initiation of adjuvant chemo/radiotherapy for this critical category of patients. Using ultrasound shears provides a wide spectrum of tissue effects via mechanical oscillation. The absence of an electric circuit in ultrasound shears reduces thermal injury and accordingly cellular damage.

objectiveComparing utilization of ultrasound shears in axillary lymph node dissection to conventional radio frequency electrosurgery in terms of operative time, post-operative drainage amount and days, post-operative pain, the incidence of seroma or infection, and lymph node yield.

methodsThis study is a randomized control trial. It includes 56 breast cancer ALND cases performed in conjunction with either BCS or MRM; being upfront surgery cases or post-neoadjuvant therapy cases, 28 patients underwent ALND using ultrasound shears and 28 underwent ALND using radio frequency electrosurgery.

resultsThe mean age of the study population was 51 ± 11.7 years, with a mean BMI of 39. The mean operative time in the ultrasound shear group was 29.4. ± 7.6 min and 31.6 ± 5.1 min in the conventional group. The mean amount of drainage in the ultrasound shear group was 319.6 ± 75.4 ml and 407.5 ± 75.2 ml in the conventional group. The mean drainage days in the ultrasound shear group were 8 ± 1 day and 12 ± 2.2 days in the conventional group. Seroma formation was recorded in 6 of the ultrasound shear groups and 9 in the conventional group. Seroma followed by infection was found in 10% of the ultrasound shear group versus 21% in the conventional group. Seroma formation and wound infection were significantly related to the conventional group (p-value = 0.01).

conclusionOur study recommends the utilization of ultrasound shears in ALND as it is a safe and accurate method that allows faster post-operative recovery with shorter drainage time and lower incidence of seroma or infection, without affecting operative time or lymph node yield.

trial registrationTrial no.: PACTR202402831197428. Date of approval: 19/02/2024.

Indexed as

AxillaBreast NeoplasmsLymph Node ExcisionSeromaAdultAgedElectrosurgeryFemaleHumansMiddle AgedOperative TimePostoperative ComplicationsAxillary lymph node dissectionBreast cancerDrainage timeSeroma formation

Identifiers

PMID39693006
PMCPMC13313864

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.